Loading...
HomeMy WebLinkAbout1992 06-22 EDAP Regular Session EDA AGENDA CITY OF BROOKLYN CENTER + JUNE 22, 1992 (following adjournment of City Council meeting) 1. Call to Order 2. Roll Call 3. Approval of Minutes: a. June 8, 1992 - Special Session 4. Discussion Item: a. Consideration of Acquisition of 5340 Colfax Avenue North under the City's Scattered Site Redevelopment Program ram P g 5. Resolutions: a. Authorizing the Acquisition of Certain Real Property within the City of Brooklyn Center and Establishing Offer of Just Compensation for Said Property Located at 5206 Drew Avenue North in Brooklyn Center b. Approving Two (2) Brooklyn Center Economic Development Authority Grants (File Nos. H -105 [8031] and H -106 [8032]) 6. Adjournment CITY OF BROOKLYN CENTER Council Meeting Date June 22.1992 Agenda It= Number REQUEST FOR COUNCIL CONSIDERATION ITEM DESCRIPTION: EDA MINUTES - JUNE 8, 1992 - SPECIAL SESSION DEPT. APPROVAL: Brad Hoffman, EDA Co nator MANAGER'S REVIEW/RECOMMENDATION: No comments to supplement this report Comments below /attached • SUMMARY EXPLANATION: (supplemental sheets attached ) RECOMMENDED CITY COUNCIL ACTION MINUTES OF THE PROCEEDINGS OF THE ECONOMIC DEVELOPMENT AUTHORITY OF THE CITY OF BROOKLYN CENTER IN THE COUNTY OF HENNEPIN AND THE STATE OF MINNESOTA SPECIAL SESSION JUNE 8, 1992 CITY HALL CALL TO ORDER The Brooklyn Center Economic Development Authority met in special session and was called to order by President Todd Paulson at 11 ;58 p.m, ROLL CALL President Todd Paulson, Commissioners Dave Rosene, and Philip Cohen, Celia Scott, and Jerry Pcdlar. Also present were City Manager Gerald Splinter, Assistant EDA Coordinator Tom Bublitz, City Attorney Charlie LeFevere, Director of Planning and Inspection Ron Warren, and Council Secretary Carla Wirth. APPROVAL OF MINUTES MAY 18. 1992 - SPECIAL WORK SESSION Therc was a motion by Commissioner Scott and seconded by Commissioner Pedlar to approve the minutes of the May 18, 1992, EDA meeting. The motion passed unanimously. MAY 26, 1992 - SPECIAL S ESSION There was a motion by Commissioner Scott and seconded by Commissioner Pedlar to approve the minutes of the May 26, 1992, EDA meeting. The motion passed unanimously. DISCUSSION ITEMS N I ERATION O C QUISITION OF SINGLE - FAMILY PROPERTIES UNDER THE EDA'S SCA TTERE D SITE Q L&MENT 7RAM The Assistant EDA Coordinator indicated staff has inspected two single - family properties as potential acquisitions under the Scattered Site Acquisition Program. He then reviewed the condition of the two properties - 5206 Drew Avenue North and 419 69th Avenue North. It was noted that both property owners initiated contact with the EDA regarding the purchase of their homcs. In response to President Paulson's question, the Assistant EDA Coordinator explained staff recommends authorization to prepare information for EDA consideration to acquire the properties. 6/8/92 . 1 - There was a motion by Commissioner Pedlar and seconded by Commissioner Scott to dire staff to prepare information for EDA consideration regarding acquisition of these propert under the Scattered Site Acquisition Program. The motion passed unanimously, REPORT ON PROPOSED REHAB GRANT H -103 The Assistant EDA Coordinator indicated staff has prepared a report on the previous $2,290 rehabilitation grant awarded to the resident of 5834 Camden Avenue North in 1980. The previous grant was used to replace the furnace. He then reviewed the items to be rcpaircd under the current grant proposal including electrical, mechanical, plumbing, wall and ceiling repair, replacement of doors and windows and house insulation. Since the existing furnace gas valve is prone to leaking, a replacement valve is also included. RES 21UTION NO 92 -19 ° Commissioner Scott introduced the following resolution and inovcd its aduptiun; RESOLUTION APPROVING ONE (1) BROOKLYN CENTER ECONOMIC DEVLLOPMENT AUTHORITY GRANT (FILE NO. H -103 [80291) The motion for the adoption of the foregoing resolution was duly seconded by Commissioner Pcdlar, and the motion passed unanimously. President Paulson declared a conflict of interest on the next agenda item and left the meeting. president Pro tem Pedlar then chaired the meeting. RE 0 •LUTIONS The City Manager introduced a Resolution Authorizing Execution of Land Disposition Agreement for 673U Perry Avenue North. He indicated this is a housekeeping resolution regarding the restriction of the sale of the property for the construction of a single- family home for low and moderate income persons. RESOLUTION NO 92 -20 Commissioner Cohen introduced the following resolution and moved its adoption; RESOLUTION AUTHORIZING EXECUTION OF LAND DISPOSITION AGREEMENT FOR 673U PERRY AVENUE NORTH The motion for the adoption of the foregoing resolution was duly seconded by Commissioner Scott, and the motion passed. Todd Paulson abstained from voting. The City Manager introduced a Resolution Amending the 1992 Economic Development Authority Budget for the Debt Service Transfer of the Earle Brown Farn1 Tax Increment Financing District Fund. 6/8/92 2 Q TIN NO 92-21 Commissioner Cohen introduced the following resolution and moved its adoption: RESOLUTION AMENDING THE 1992 ECONOMIC DEVELOPMENT AUTHRITY BUDGET FOR THE DEBT SERVICE TRANSFER OF THE EARLE BROWNOARM TAX INCREMENT FINANCING DISTRICT FUND The motion for the adoption of the foregoing resolution was duly seconded b Commissioner Scott, and the motion passed unanimously. y The City Manager introduced a Resolution Amending Economic Development Authorit Resolutions Nos. 92 -03 and 92 04, y RES L TI ON No, g _2 Commissinncr 3cort introduced the fallowing resolution and moved its adoption: RESOLUTION AMENDING ECONOMIC DEVELOPMENT AUTHORITY RESOLUTIONS NOS. 92 -03 AND 92.-04 The motion for the adoption of the foregoing resolution was duly seconded b Commissioner Cohen, dnd the motion passed unanimously. Y ADJOURNMENT Where was a motion by Commissioner Rosene and seconded b Commis ; adjourn the meeting. The motion passed unanitnousl . The Brookl s ocicr Scott to Development Authority adjourned at 12:05 am. on June 9, 1992, Center Economic Todd Paulson, President Recorded and transcribed by: Ala Wirth Northern C%OuntieS Secretarial Services 6/8/92 3 . CITY OF BROOKLYN CENTER council Meeting Date June 22.1992 Agenda Item Numbe REQUEST FOR COUNCIL CONSIDERATION 0 ITEM DESCRIPTION: CONSIDERATION OF ACQUISITION OF 5340 COLFAX AVENUE NORTH UNDER THE CITY'S SCATTERED SITE REDEVELOPMENT PROGRAM DEPT. APPROVAL: Tom Bublitz, Assistant EDA dadrdinator MANAGER'S RE VIEW/RECOMWE NDATI ON. No comments to supplement this report . Comments below /attached SUM IARY EXPLANATION: (supplemental sheets attached YES • On May 27, 1992, City staff was contacted by g a real estate agent with Coldwell Banker who is listing the property at 5340 Colfax Avenue North. The agent representing the owner of the property requested the EDA to consider purchase of the property. Upon request of the owner, the City Building Inspector and I inspected the property at 5340 Colfax Avenue North. The eBil Building Inspector's mem r g memorandum, included with this request, summarizes the condition of the property. Essentially, the Building Inspector's memorandum describes a house that is in need of major expenditures to bring the property up to Section 8 standards that are used in the City's rehabilitation grant program. The house was built in 1910, and has 640 square feet of finished space. A copy of a photo of the property is included with this report. The lot size is 84 x 120, and the City assessing records show a valuation of $46,900.00. The ro er is located in an area that has under P p ty gone one redevelopment project already (5345 Colfax Avenue North). EDA staff believes this home should be considered for acquisition under the Scattered Site Redevelopment Program. If the EDA agrees with this recommendation, the staff would return to the EDA with a full appraisal report for consideration. RECOMMENDED NDED ITY COUNCIL ACTION Staff recommends motion to authorize staff to roceed with appraisal of the roe at 5340 P PP property rt3' Colfax Avenue North. MEMORANDUM To: Tom Bublitz, EDA Assistant From: Dave Fisher, Building Inspector Date: June 12, 1992 Subj: 5430 Colfax Avenue North, Brooklyn Center, MN 55430 Results of inspection at 5430 Colfax Avenue North 1. Electrical service, 30 amp. a.) Each bedroom has 1 outlet. Section 8 standards require 2 outlets. 2. Substandard Plumbing a.) Currently "S" traps. b.) Improper venting, not vented properly. c.) Venting undersized. 3. Siding ld and in need of repair. g p 4. Roof old and in need of repair /replacement. 5. windows are single pane and substandard. 6. Bathroom is small and toilet does not meet code. 7. There is a well that needs to be abandoned. 8. Furnace, gravity style, not efficient. 9. Doors are old and drafty. Z.+ f'i' s ri t f, e•, . aW� r A "'i • il+, J�... t � � :yam L� j �k, "•fi.= 3. :- ! � ", r t l^ +�..h � "�` a•.`al� �l M � � r as+ • w �, n 3 w .� `��•" ,• i 7+- � c4 � � t :. � r ry � t '� S iY. - `43 "x yfl � .' '�Cp• •�? y e } L' C��ai� ��f r t"ytt r R�1)• _ tr.$'4. ' . l . \, � ty�?yt't. a a;♦ r •�{ � -. 'sr x S' ' �` J/ �' ♦ �l e k S 3 Z ._ ► l ♦ ! e }, , �i�. �.i w. ,� , ��, 1, .•ji _•" �� r. :- ��r � a .�.• i - �.M4 s. � `� S e r r r y � 4 i �.• �.ti6 �4� R = ..� �.•�„�• d._ r � �•f. . r im CITY OF BROOKLYN CENTER camea Meeting Date June 2 11 992 Agenda Item Number Scz� REQUEST FOR COUNCIL CONSIDERATION ITEM DESCRIPTION: RESOLUTION AUTHORIZING THE ACQUISITION OF CERTAIN REAL PROPERTY WITHIN THE CITY OF BROOKLYN CENTER AND ESTABLISHING OFFER OF JUST COMPENSATION FOR SAID PROPERTY LOCATED AT 5206 DREW AVENUE NORTH IN BROOKLYN CENTER DEPT. APPROVAL: Tom Bublitz, Assistant EDA Coordinator MANAGER'S REVIEW/RECONEWENDATION: . No comments to supplement this report . Comments below /attached SUMMARY EXPLANATION: (supplemental sheets attached Yes The EDA is requested to approve a Resolution authorizing the making of an offer to acquire h P g g q to property at 5206 Drew Avenue North in Brooklyn Center. This property was reviewed as a discussion item by the EDA at the June 8, 1992 EDA meeting nd the EDA approved a mo g pp of on to authorize staff to present a proposal for acquisition of this property. The EDA Board has received a copy of the appraisal report and review appraisal on the single family property located at 5206 Drew Avenue North. Also included is a memorandum from the City Assessor regarding the estimated market rental rate of the property at 5206 Drew Avenue North. Since the estimated rental rate for this property exceeds the Section 8 fair market rents for a one bedroom unit, the EDA is exempt from the one for one housing replacement rule which requires that any affordable units demolished must be replaced on a one for one basis within a three year period from the demolition. Staff became aware of the property initially through a phone call from the owner on April 9, 1992. At that time, the owner indicated he was interested in the City purchasing his property. On April 14, 1992, the City Building Official and I inspected the property at 5206 Drew and met with the owner to discuss the possible acquisition of his property. The nature of this initial visit was essentially to inspect the condition and size of the property. I also requested the owner to write a letter stating his request to have the EDA purchase his property. A copy of the letter is included with this council request form. The acquisition is being approached as a voluntary sale by the owner; and, as such, he would be required to formally waive any consideration of relocation benefits. It should also be noted that the owner of the property at 5206 Drew has homesteaded residential property in another county in Minnesota. The review appraisal has indicated a range of value for the property between $31,000.00 and $34,000.00. The initial appraisal report showed a value of $34,000.00 for the property. I have spoken with the appraiser who prepared the initial appraisal report and he has concurred with the review appraisal establishing a range of value between $31,000.00 and $34,000.00. Funding for the project would be from Community Development Block Grant (CDBG) funds. An estimated budget for acquisition and demolition of the property is shown by the following: COST ITEMS COST Acquisition cost of property $31,000.00 Appraisal fee 475.00 Demolition 5,000.00 Legal costs 1,500.00 Closing costs (including title transfer and prorated taxes) 1,800.00 Administration 1,200.00 Incidental expenses (certified mail, messenger service, office supplies, etc.) 150.00 TOTAL: $41,125.00 RECOMMENDED CITY COUNCIL ACTION Staff recommends approval of the resolution which would authorize staff to proceed with the negotiations for the acquisition. Oroo 11 W 3v 1 Jkih j ) c Grce(c P 4 rKwq/ co� <f 7 Ce v&er 9 A) 5 Sg3Q r TC , 1 vl-\ (/0 V I /+ n q o Y 0` l t� e� air i \/ 0 U Y 11 J 1 �vuj ('ev �i z�f��� �Qr'c�c`Y'a,� , A v e 4L'If Nov,fk i s Yk? C �ki ci( I P- your cu c- -e 0 5 i VI C Pv i� ct �-{ a I e ►� CITY 6301 SHINGLE CREEK PARKWAY OF BROOKLYN BROOKLYN CENTER, MINNESOTA 55430 TELEPHONE: 569 -3300 C ENTER FAX: 569 -3494 EMERGENCY - POLICE - FIRE 911 MEMORANDUM TO: Tom Bublitz Assistant EDA Coordinator FROM: Mark Parish City Assessor ' DATE: May 19, 1992 RE: Appraisal Review 5206 Drew Avenue North -------------------------------------------------------------------------------------------------------------------- Per your request, I have reviewed the Appraisal Report of the property made by Scott Renne. While I am in general agreement with his conclusion, I believe some consideration ought to be given to the locational adjustment. The subject is adjacent to a large apartment complex which has a negative impact on both value and marketability. The impact on marketability is the most difficult to measure and directly affects the value. The group of buyers with interest in a one bedroom house of less than 600 square feet (sf) is, at least, limited. Any negative factor will cause them to discount a potential offer or consider other offerings. As the subject is just over 500 sf and the "competition" in this segment of small houses are generally larger than the subject, the locational factors are critical. Sales in Brooklyn Center indicate that residential properties adjacent to apartments sell for five percent less than properties without the apartment influence. As the project adjacent to the subject has a high rate of turnover (only month -to -month tenants, no leases) and an unkept exterior, I believe the subject would experience a similar adjustment. Mr. Renne makes an adjustment at five percent for Minneapolis location versus Brooklyn Center. Accepting that as accurate, it would be offset by the apartment adjustment. � a 1986ALL+IME3tlCA(XfY� 1; �I Tom Bublitz May 19, 1992 Page Two Comparables (Camps) one through five are closely grouped at 50th and Girard and do not have an apparent adjacent influence. Comp six is in a similar residential neighborhood, but without an apartment influence. Changing the location adjustment to $0 in one through five and - $2,300 in six, the indicated value of the subject becomes: Comp 1 = $31,275 Comp 4 = $29,275 Comp 2 = $33,750 Comp 5 = $32,750 Comp 3 = $33,650 Comp 6 = $33,950 In his summary table on page 15, Mr. Renne concludes a value of $34,000 and that Comparable Six is most similar. The locational adjustments I recommend for adjacent influence support his conclusions. Finally, while I agree with his conclusion, I am troubled by the fact that the subject is smaller than all six of the comparables. In this size property, 100 square feet is a large difference. Therefore, comparable six is definitely better than one through five. However, as it is still larger (506 sf v. 576 sf or + 14 %). I believe it defines the upper end of a value range. I believe the value of the subject is in a range of $31,000 to $34,000. If you have additional questions or comments on this matter, please contact me at 569 -3355. CITY 6301 SHINGLE CREEK PARKWAY OF BROOKLYN CENTER, MINNESOTA 55430 BROOKLYN TELEPHONE: 569 -3300 CENTER FAX: 569 -3494 EMERGENCY - POLICE - FIRE 911 MEMORANDUM TO: Tom Bublitz Assistant EDA Coordinator FROM: Mark Parish City Assessor DATE: June 8, 1992 RE: Estimated Market Rental Rate 5206 Drew Avenue North, Brooklyn Center You recently requested an estimate of the fair market rental rate for this property. Based on a review of rental comparables and current market levels, a one - bedroom home with no garage could be expected to rent for $375.00 to $525.00 per month. This rent would typically include sewer and water, but all other utilities including gas, electric, cable television and telephone would be paid by the tenant. While the location and condition of the property are good, the lack of a garage and the house size would hinder the marketability. Therefore, I would expect it to rent towards the middle of the typical range, at approximately $450.00. Utility costs of $30.00 for natural gas heat, $10.00 for gas water heating and stove, $22.00 for electric, and $17.00 for trash collection total at $79.00. Thus, my estimate of Fair Market Rent, including utilities, is $529.00. If you have further questions on this matter, please contact me at 569 -3310. a Commissioner introduced the following resolution and moved its adoption: EDA RESOLUTION NO. RESOLUTION AUTHORIZING THE ACQUISITION OF CERTAIN REAL PROPERTY WITHIN THE CITY OF BROOKLYN CENTER AND ESTABLISHING OFFER OF JUST COMPENSATION FOR SAID PROPERTY LOCATED AT 5206 DREW AVENUE NORTH IN BROOKLYN CENTER WHEREAS, the Brooklyn Center Economic Development Authority has received the following items relative to the appraisal of the real property located at 5206 Drew Avenue North: A. Appraisal Report dated May 3, 1992; B. Review Appraisal dated May 19, 1992; and WHEREAS, the Economic Development Authority for the City of Brooklyn Center (EDA) is authorized, pursuant to Minnesota Statutes Section 469.012, Subd. 7, within its area of operation, and without the adoption of an urban renewal plan, to acquire real property and to demolish or remove the buildings and improvements thereon; and WHEREAS, the owner of the property located at 5206 Drew Avenue North in the City of Brooklyn Center ( "the property ") has requested that the EDA consider the purchase of the property; and WHEREAS, the building located on the property is substandard and obsolescent and that such condition and obsolescence is detrimental to the public health, safety and welfare of the community; and WHEREAS, the EDA has received an appraisal and a review appraisal which establishes that the market value for the property is in a range between $31,000.00 and $34,000.00. NOW, THEREFORE, BE IT RESOLVED by the Economic Development Authority for the City of Brooklyn Center as follows: 1. The EDA hereby finds and determines that the property is substandard and obsolete within the meaning of Minnesota Statutes Section 469.012. 2. The appraisal documents described in paragraph 1 of this resolution are hereby accepted and the fair market value range of $31,000.00 to $34,000.00, established by the appraisal documents, is hereby accepted. 3. The fair market value of $31,000.00 for the property, established by the appraisal documents, is hereby accepted and established as just EDA RESOLUTION NO. compensation for the real property located at 5206 Drew Avenue North. 4. The Executive Director is authorized to make a written offer of $31,000.00 to the owner of the real property at 5206 Drew Avenue North for the acquisition of the property, contingent on release of the property from the Department of Housing and Urban Development (HUD) environmental conditions and to take such further action as may be necessary to acquire the property. Date Todd Paulson, President The motion for the adoption of the foregoing resolution was duly seconded by Commissioner and upon vote being taken thereon, the following voted in favor thereof: and the following voted against the same: whereupon said resolution was declared duly passed and adopted. CITY OF BROOKLYN CENTER council Meeting Date rune n. 1992 Agenda Item Number REQUEST FOR COUNCIL CONSIDERATION ITEM DESCRIPTION: RESOLUTION APPROVING TWO (2) BROOKLYN CENTER ECONOMIC DEVELOPMENT AUTHORITY GRANTS (FILE NOS. H -105 [8031] and H -106 [8032]) DEPT. APPROVAL: J�--� "/ - Tom'Bublitz, Assistant EDA oordinator MANAGER'S REVIEW/RECOMNIENDATION: No comments to supplement this report Comments below /attached SUNDIARY EXPLANATION: (supplemental sheets attached )Les • I have received two (2) applications for rehabilitation grants (File Nos. H -105 [8031] and H -106 [8032]). Attached are the applications and recommendations for work to be performed on the homes. I recommend approval by the EDA. The information is private and not available to the general public. Our records indicate no previous grants were done at the property under File No. H -105. File No. H -106 received a grant in 1980. The work done at this time included the following items: 1. Reroof house; 2. Insulate basement rim joist; 3. Insulate ceiling to R -38; 4. Install correct ventilation; 5. Correct kitchen venting; 6. Repair and adjust windows and weatherstrip; 7. Insulate casing around living room picture window; 8. Install 100 amp service and bring house up to code; and 9. Install new water conditioner. The present rehabilitation work proposed includes two items related to the previous grant. They are installation of a kitchen vent fan and installation of a water softener. In the 1980 grant, the kitchen vent pipe was corrected to vent to the outside, but did not include replacement of the fan. A water softener was included in the initial grant in 1980. RECOMMENDED CITY COUNCIL ACTION Motion to adopt Resolution Approving Two (2) Brooklyn Center Economic Development Authority Grants (File Nos. H -105 [8031]; and H -106 [80321). Commissioner introduced the following resolution and moved its adoption: EDA RESOLUTION NO. RESOLUTION APPROVING TWO (2) BROOKLYN CENTER ECONOMIC DEVELOPMENT AUTHORITY GRANTS (FILE NOS. H -105 [8031] AND H -106 L8022_ WHEREAS, the Brooklyn Center Economic Development Authority established a Home Rehabilitation Grant Program to assist low and moderate income individuals in the maintenance and repair of their homes; and WHEREAS, the Brooklyn Center Economic Development Authority has received two (2) applications (file nos. H -105 [8031] and H -106 [8032]) from eligible individuals to receive grant assistance; and WHEREAS, an inspection by the City of Brooklyn Center has determined that the work is necessary and appropriate under the Brooklyn Center Economic Development Authority Grant Program; and WHEREAS, the estimated cost of the proposed grant applications is estimated at $20,000. NOW, THEREFORE, BE IT RESOLVED by the Brooklyn Center Economic Development Authority that: 1. The Brooklyn Center Economic Development Authority does approve the two (2) housing rehabilitation grant applications (file nos. H -105 [8031] and H- 106 [8032]) as recommended by the staff. 2. That the work be performed as recommended in the request for council consideration form dated June 22, 1992, and that the applicants be directed to obtain the necesary bids for staff review and approval. 3. The project shall not exceed the grant limit of $10,000 per house. Date Todd Paulson, President The motion for the adoption of the foregoing resolution was duly seconded by Commissioner and upon vote being taken thereon, the following voted in favor thereof: and the following voted against the same: whereupon said resolution was declared duly passed and adopted. R • R l. �IVEL • f' UHC /ssa APR 1(; 1992 URBAN HENNEPIN COUNTY HOUSING REHABILITATION DEFERRED LOAN PROGRAM M ETRO H.R.A. HOMEOWNER APPLICATION FOR GRANT HOUSEHOLD INFORMATION -- Please Print Name 1 L I L D R E D , (, 0- S TA p First Name t` , � of Spouse N S cl ) Address 3 �. V VC- E'N T Ayr-- ffO R A H Home Phone - ,S - do - ' - 6v O 7 S City q hf:i'V AIVI, Zip Code-5]S Work Phone Ye f�Y E City of residence if other than mailing address Marital Status (check one) married, single, divorced, separated, widowed Race (check one) �� White, Black, American Indian /Native Alaskan, Hispanic, Asian or Pacific Islander The information concerning Minority Group Categories is requested for statistical purposed only so that Hennepin County may determine the degree to which its programs are utilized by Minority households. INCOME INFORMATION _ "Income" means an y income received from any source by a Reside t. 2 �"� O v List all the people in occupying your house for at least nine months of the year (including yourself). Include ages and incomes. Include any income derived from rent. Total number of residents in the household How many renters? OFFICE USE ONLY income of # in household ' names of ages of residents residents residents per month source of income verified incomes r JU-1 22 ED COOL ST-AD - �7 r_ _ 1,1- P,. �`. r`_ `?ltr't• $ . 3��0, /�{ y j'111. I1'rrr'f•r� '��� r . f i> >� $ -- L o w - IZ [Fv -?, �� �, 7�� �1�^ 7;,�. rl r'� , ��'�r� {t. $ as, g•23�� A lj �� I7/1/';F - `�•�';�.�, --�f � /' `' � .'{"crr�•c�,'�- ��c���',l >rt� -n Total Income $ 1 ! , "' 'per month - $ per year $ 3 3 1 income per month RETURN APPLICATION TO, $ T ; 5� 1�1(a , U 2 . M4. Jim Oupne (291 -6573) income per year Me•tno NRA Meau Pan k Cen•tne 230 Ea6.t 5.t S.tnee•t St. Paue, MN 55101 APR 1 1992 ASSET INFORMATION METRO List the cash value of assets held by all residents of your household. If money is owed on any item, the value listed should equal the market value of the item minus the amount that is owed. OFFICE USE ONLY verified assets 1 . CASH on hand .......... ..............................$ $ 2. CASH in checking accounts ........................... $ �� . �;` " $ x'31'} „ �j� S '`� -a Z- 3. CASH in saving accounts ( including those held....... $ 1.T in trust) 4. Cash value of Securities or U.S. Savings bonds ...... $ 5. Redemption value of life insurance policies ......... $ 6. Current Market Value of real estate, NOT INCLUDING the property to be improved and up to 2 surrounding acres. Include 100% of the outstanding balance owed to you on property sold on Contract for Deed ... $ $ 7. Other personal property (excluding household furnishings, clothing and one personal vehicle) ..... $ '--- $ TOTAL ASSETS....... n .......... PROPERTY INFORMATION - 2S c7cY is� l Provide the following nform - 6 zti�n about the property to be improved with this deferred loan. 1. Is your property: a sin le famil house g y a duplex . 2. How many years have ou lived in the house ? 3. What is the approximate age of the house? 4. Do you have any outstanding mortgage(s) on the house? Yes No If yes, with whom? (use additional sheet if necessary) Amount $ 5. Do you have any outstanding Contract(s) for Deed on the house? Yes No If yes, with whom? (use additional sheet if necessary) Amount $ 6. Have you received a Housing Rehabilitation Grant or Loan "before? 1"" Yes No If yes, from whom? A —t �� ti,`c Amount $ • Amount $ 2 1992 PLEASE READ CAREFULLY METRO H.R.A. Urban Hennepin County or an authorized representative shall have the right to inspect the property to be improved at any time from the date of the Deferred Loan upon given due notice to the occupant(s). Any person who makes a false statement or misrepresentation in connection with the application for or use of Urban Hennepin County Deferred Loan funds shall be subject to a fine or imprisonment, or both, under the provisions of the Minnesota Criminal Code, and /or may be required to return all or part of the Deferred Loan Funds to Urban Hennepin County. I. the undersigned, certify subject to penalty under law that the above information is true and correct to the best of my knowledge and belief, and that the provisions stated are accepted and agreed to. z�e -Q_ e-2--r L� �� Q. fL ��L', l s , / 9 4 Z applicant signat re date of application Note: All names and financial information provided on this application are considered private data on individuals and are subject to privacy of information provisions, pursuant to State Statute. 3 3 • RECEIVED UHC/888 + APR 1(; 1992 URBAN HENNEPIN COUNTY CDBG HOUSING REHABILITATION PROGRAMS [A TRO Hie, INDIVIDUAL DATA CONFIDENTIALITY YOUR RIGHTS AS A SUBJECT OF DATA In accordance with the Minnesota Government Data Practices Act, Hennepin County is required to inform you of your rights as they pertain to the private information collected from you. Private data is that information which is available to you, but not to the public. The personal information we collect about you is private. The information collected from you or from other agencies or individuals authorized by you is used to determine your eligibility for a home improvement loan. You are not required to provide information relating to your marital status and race; however, this information is vital to determine to what extent our programs are used by minorities. All other information on the form is needed to determine your eligibility. If you will not supply the required information, the agency processing your application will not be able to determine your eligibility for the loan. The dissemination and use of the private data collected is limited to that necessary for the administration and management of home improvement loans. Persons or agencies with whom this information may be shared include: 1. Hennepin County personnel administering home improvement loans or monitoring the performance of other administering entities. 2. Personnel of any City cooperating with the County in administering home improvement loans. 0 3. City council members: only that information needed to approve the application for loan funds and /or payments to contractors. 4. Federal, state, county, local and contracted private auditors. 5. Authorized personnel from the U.S. Department of Housing and Urban Development. .6. The contract for deed holder: only to that you are a loan recipient and that amount of the grant. 7. Law enforcement personnel in the cases of suspected fraud. 8. Those individuals or agencies to whom you give or express written permission. 9. Secretary of the Treasury: only your name and address, for purposes of avol "ing the acceptance of a tax credit for energy improvements made with loan funds. Unless otherwise authorized by statute or federal law, other government agencies utiliz- ing the reported private data must also treat the information as private. You may wish to exercise your rights as contained in the Minnesota Government Data Practices Act. These rights include the right to: 1. See and obtain copies of the data maintained on you, 2. be told the contents and meaning of the data and, 3. contest the accuracy and completeness of the data. To exercise these rights, contact Jim Graham, Office of Planning and Development, Development Planning Unit, 822 South Third Street Suite 310, Minneapolis, Minnesota 55415, Telephone 348 - 5619. I hereby declare I have received a copy of the - Individual Data Confidentiality orm and* that I have read it and understand my rights as a subject of data, y date loan recipient MEMORANDUM TO: Tom Bublitz, Assistant EDA Coordinator FROM: David Fisher, Building Inspector DATE: June 17, 1992 SUBJECT: Rehabilitation Grant for 5842 Vincent Avenue North Homeowner: Mildred J. Bolstad H -106 (8032) Subject property is a four bedroom rambler, approximately 36 years old. The major deficiencies noted: Cracked foundation, old furnace, abandoned well and inoperable storm windows. The following list of rehabilitation items would improve this home greatly: Electrical 1. Install 3 prong plugs throughout dwelling so they are grounded properly. Mechanical 1. Provide heat loss calculations for dwelling and install new furnace to code. 2. Provide combustion air. 3. Provide set back thermostat. Plumbing 1. Install approved gas valve on existing water heater. 2. Disconnect abandoned well properly. 3. Repair or replace inoperable water softener. 4. Install new bathtub wall enclosure and shower curtain rod. 5. Install new laundry tub. 6. Repair floor drain. Memorandum, Page 2 June 17, 1992 Bolstad Plumbing, Continued 7. Install back flow preventers on all outside spigots. 8. Repair all vents and drains by replacing missing plugs. 9. Install new water closet in main bathroom. 10. Replace water valve to water closet main bathroom. I Miscellaneous 1. Replace handrail to front steps. 2. Repair foundation by filling joints with mortar and tuck pointing and raking out to a minimum depth of 1/2 inch and wet. 3. Repair ceiling in bathroom. 4. Repair walls in bathroom; tile falling off walls. 5. Replace floor covering in kitchen, main bathroom and living room. 6. Weather seal rear exterior door. 7. Replace front exterior door. 8. Adjust doors on all four bedrooms so they close and latch. 9. Replace storm windows (3 kitchen, 1 living room, 2 middle left bedroom, 2 right bedroom, 3 right middle bedroom, 2 left bedroom and 1 in second bathroom). 10. Replace living room window (the large picture window). 11. Replace bathroom window with glass block. 12. Repair kitchen ventilation fan. 13. Cover all windows, door trim and sills with aluminum to specifications. Memorandum, Page 3 June 17, 1992 Bolstad Miscellaneous, continued 14. Cover all soffit and fascia with aluminum to specifications. 15. Scrape and paint gutters. 16. Check all downspouts and gutters and repair or replace. 17. Replace overhead garage door. 18. Trim all trees close to house and garage roof. URBAN HENNEPIN COUNTY HOUSING REHABILITATION GRANT PROGRAM PROPERTY INSPECTION REQUEST TO COUNCIL: Tune 22, 1992 H -106 (8032I APPLICANT INSPECTION Name Mildred J. Bolstad Staff Tom Bublitz /Dave Fisher Address 5842 Vincent Avenue North Date June 12, 1992 Brooklyn Center, MN 55430 Time 1:30 P.M. Phone 560 -6075 Inspector David Fisher Building Age: 36 years Garage: Detached TABLE OF CONTENTS RT PAGE 1 ® HANDRAIL - GUARDRAIL $ 1 Where required, Height of, Baluster Spacing and Installation, Specification for 2 ❑ INTERIOR - EXTERIOR STAIRS $ 1 Repair or Replacement of, Rise and Run and Installation, Specification for 3 FOUNDATION $ 2 Repair of —Tuck Pointing Insulation Installation and Specification for 14 4 ❑ CRAWL SPACE: $ 2 Insulation of and Vapor Barrier, Installation for 5 ❑ BASEMENT FLOOR $ 2 Repair of 6 ❑ POST AND BEAM: $ 3 Repair of, Replace 7 ❑ ACCESSIBILITY IMPROVEMENT $ 3 4, For Barrier Free and Handicapped Persons 8 ELECTRICAL $ 3 Upgrade Service, Unprotected Conductor,Washer, Dryer, Hanging Receptacle, Furnace and Kitchen Circuits Wall Receptacle, Ground Fault 4 9 ❑ ELECTRICAL MAST: $ 4 Relocation of 10 ® MECHANICAL $ 4 Enclosed Space Ventilation, Replace Furnace Thermostat, Chimney, Registers, Ductwork 11 ® PLUMBING: $ 5 Water Heater Replacement, Cold Water Shut -off, Gas Valve T.P.R. Valve, Vent Connector, Dryer Gas Valve, Dryer 6 Ventilation, Open Gas Device,Well Abandonment, Plugged Sewer, Water Softener, Kitchen Sink Vent, Trap, Water Supply, Lavatory Vent, Trap, Water Supply, Water Closet and Sealing Gasket, Bathtub Vent, Trap, Wall Enclosure, Laundry Tub Vent, Trap, Floor Drain Plumbing Fixture Material and Performance Specifications 7 for, Drain Tile, Main Water Line Septic System, City Sewer .8 -1- TABLE OF CONTENTS PART PAG 0 2 ® CEILINGS $ 8 Repair of 13 [ WALLS: $ 8 Repair of 13 Ceiling and Wall Performance and Material Specifications for 9 -1 14 ( FINIS FLOORS: $ 10 -1 Replacement ement of, Performance and Material Specifications for 15 X EXTERIOR DOORS: $ 1 Repair - Refinish of, Weather Sealing, and Replacement of, Performance Specification for 16 ❑ EXTERIOR STORM DOORS: $ 1' Repair - Replacement of, Material Specification for 17 INTERIOR DOORS $ 1 Repair - Replacement of, Performance and Material Specifications for 18 ( EXTERIOR STORM AND SCREEN WINDOWS $ 1- Repair - Replacement of, Material Specification for 0 9 X HOUSE WINDOWS: 13 Repair - Refinish of, Weather Sealing of, Replacement of,. Material and Performance Specification for 20 ❑ INSULATION: $ 14 -1_= A ttic, Wall, Foundation, Rim Joist Installation, Material and Performance Specification for, Code Requirement Z1 ® VENTILATION: $ 1: Provision of Attic, Kitchen, Bathroom, Repair of, Material and Performance Specification for 22 EXTERIOR SIDING: $ 1 Installation, Repair or Replacement of, Soffit and Facia, Window, Door and Cornice Trim, Material and Performance Specification for 23 ® EXTERIOR PAINTING: $ 1 Material an Performance Specification for 24 ❑ GUTTERS AND DOWNSPOUTS: $ 1 Provision for ana eplacement of, Material and Performance Specification for �5 ❑ ROOFING: $ l Re-pair - Replacement - Removal of, Material and Performance Specification for -2- TABLE OF CONTENTS PART PAGE 26 Q CHIMNEY Repair - Reline - Replacement of $ 5 -19 27 KITCHEN & BATHROOM CABINETS $ 19 28 Q SMOKE DETECTORS Installation of 20 29 Q GRADING Material and Placement Specification for, Seeding and $ 20 Sodding of 30 Q EXTERIOR CONCRETE WORK Replacement - Repair of, Sidewalks, Garage Apron, Etc. $ 20 31 Fx — x MISCELLANEOUS: $ 20 TOTAL $ Contractor Nave: Address: City State Phone: Home Work Homeowner Name: Mildred J. Bolstad Address: 5842 Vincent Avenue North (55430) Phone: 560 -6075 H# 106 (8032) Contractor Signature Date -3- 1. INSTALL HANDRAIL: Q Basement Stair 13R Front Stair ❑ Rear Stair ❑ Upper Level Stair One handrail shall be installed on stairways 44 or less in width, except that stairways open on one or both sides shall have handrails provided on the open side or sides. Handrails shall not be less than 30" nor more than 34" in height above stair tread. Unenclosed floor, open landings and ramps at a height of over 30" from floor or grade shall have a guardrail. Guardrail shall not be less than 36 in height and shall have intermediate rails or an ornamental pattern such that a sphere 6 in diameter cannot ass through. P P m c ro h Materials and pass finish shall be specified in the Scope of Improvements and installation shall be in compliance with the State Building Codes. [Xj( Addition: Replace handrail to front step. 2. INTERIOR - EXTERIOR STAIRS pg ❑ Repair ❑ Basement Q Second Storey ❑ Front ❑ Rear Entrance Stairs ❑ Replace ❑ Basement ❑ Second Storey Q Front Q Rear Entrance Stairs Stair riser to be a minimum of 4" to a maximum of 7 " high. Stair tread to be a minimum of 11" wide. Wood stair stringer shall be of 2 x 10 nominal stock. Exterior stairs can be of treated stock or concrete having footings 42" minimum below grade. Addition: -1 - 3. REPAIR FOUNDATION: %M All joints shall be completely filled with mortar. Fg Tuck pointing shall be done only after the joints have been raked out to a minimum depth of 1/2" and wetted. 5 Addition: Repair crack in foundation. 4. CRAWL SPACE: NA Either insulate perimeter foundation wall to R -11 or floor to a minimum of R -19. A 6 mil. polyethylene plastic vapor barrier shall be installed over dirt area and be weighted by sand, rocks or other non -wood materials. Addition: 5. BASEMENT FLOOR: OK [I Patch holes and large cracks. [� Addition: -2- 6. POST AND BEAD: OK ❑ Repair or replace as ;narked. Q Addition: 7. ACCESSIBILITY IMPROVEMENTS OK ❑ Refer to Minnesota State Building Code Chapter 55 for accessibility architecture specifications. The type and scope of accessibility improvements shall be at the discretion of the Grant Administrator. Q Addition: 8. ELECTRICAL: OK ❑ Install new U.L. certified 100 amp service panel and circuit breakers. ❑ Relocate unprotected plastic coated conductors to center of wood joist or in metal protective tubing located in ❑ Provide grounded receptacle for: ❑ Washer & Dryer on a separate 20 amp circuit. ❑ ;dater Softner. ❑ Other ❑ Replace hanging light or receptacle with porcelain fixture mounted on an approved box and properly grounded. ❑ Provide separate 15 amp circuit to furnace. OK ❑ Provide separate 20 amp circuit to kitchen countertop work area receptacles. -3- ELECTRICAL CONTINUED ❑ Add wall receptacle in; j❑ kitchen; ❑ in dining room; ❑ bedroom bedroom ❑ bedroom bedroom ❑ living room ❑ bathroom ❑ with ❑ without ground fault. ❑ laundry room X� Addition: Install 3 prong plugs throughout house as needed. 9. ELECTRICAL MAST; pg [❑ Relocate ❑ Other ❑ Addition: ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE TO THE NATIONAL ELECTRICAL CODE. 10. MECHANICAL: [X Provide ventilation of enclosed furnace space. ® Provide heat loss calculation of dwelling and install new heating manufacturer's instructions capable to meet the heat loss. The minimum AFUE shall be listed at 801 and shall include damper efficiency. New appliance shall be AGA or UL listed and orsat tested. -4- ❑ Replace gas valve with approved lever handle gas valve or ball valve Replace vent connector from furnace to chimney with 26 gauge galv. ❑ P sheet metal vent materials. ® Provide combustion air ® Provide set back thermostat. ❑ Reline existing Class B Chimney to expel water heater or other gas appliance combustion gases if new heating appliance is vented through the side wall. ❑ Remove ❑ Reline existing Class B Asbestos Chimney. ❑ Add warm air register in ❑ Add return air register in ❑ Add Duct work _ ❑ Addition: ALL MECHANICAL WORK SHALL BE IN COMPLIANCE WITH STATE MECHANICAL CODES. 11. PLUMBING pR ❑ Install new gallon energy miser water heater having AGA or UL listing complete with necessary gas piping tested for leaks, new lever handle gas valve or ball valve, new vent connector sealed and secured at all joints, new temperature pressure relief valve with 3/4 overflow tube extending to 6 above finished floor. Water heater shall be warranted for five years. ❑ Install cold water shut off valve on existing water heater. Install approved gas valve on existing water heater. -5- PLUMBING continued ❑ Install temp., pressure, relief valve on existing water heater. [j Install new vent connector on existing water heater. ❑ Install new approved gas valve on gas dryer. ❑ Vent gas dryer to outside air. ❑ Plug or cap open gas valve or fitting located at or near Disconnect existing well water and reconnect water service to City water with meter and reconnect electrical ground to City side of water meter. Well to be properly abandoned, inspected and approved by the State Health Department or City Sanitarian. ❑ Rout out main house sewer and clear stoppage. t& Repair or replace inoperable water softener. ❑ Install new kitchen sink vented to outside air. ❑ Install new kitchen sink water supply tubes and valves. ❑ Install new kitchen sink trap. ❑ Install new lavatory sink vented to outside air. ❑ Install new bathroom lavatory water supply tubes and valves. ❑ Install new bathroom lavatory trap. ❑ Install new bathroom water closet complete with seat and shut off valve. ❑ Install new water closet setting seal gasket. ❑ Install new bathtub vented to outside air. ❑ Install new bathtub waste trap. �g Install new bathtub wall enclosure and shower curtain rod. Install new laundry tub ❑ Install new laundry tub waste trap. IN Floor Drain XR Inoperable ❑ Install Other 1. Install back flow preventer. 2. Repair all vents by replacing missing plugs or replacing pipe. -6- PLUMBING continued ' Q New kitchen sink shall be 33" x 22" self- rimming, unless otherwise specified in the Scope of Improvements. Sink shall be stainless steel or cast iron and faucets shall be either single lever or two handle. a. Garbage disposal is only an acceptable work item in these two circumstances. Q 1. reinstallation of existing disposal when installing a new sink. ❑ 2. removing and disposal. Q New bathtub shall be cast iron, fiberglas or steel. Faucets shall either be single lever or two handle. Color selection shall be limited white unless specified to match existing color. Installation of a fiberglas tub insert is at the discretion of the Grant Administrator. Q New lavatory shall be wall -hung or with vanity. Trap shall be .17 gauge. Color selection shall be limited to white unless specified to match existing color. Refer to Carpentry section for dabinet specification. ® New water closet shall be viterous china with close coupled tank, include seat and anti - siphon ballcock. Color selection shall be limited to white unless specified to match existing color. j New laundry tub shall be fiberglas and securely attached to wall or free standing. Faucet shall be stainless steel or brass type and nonthreaded or with a vacuum breaker. Q Provide basement interior perimeter wall drain tile system and floor sump pump. Sump pump shall discharge to an exterior french drain or City storm sewer. French drain shall be located a minimum of ft. from foundation wall and be filled with a minimum of cubic feet of 3/4" stone. Stone shall be topped with sod or reseeded to match existing landscape. ❑ Addition: Q Provide Municipal Water - House connection to municipal water line shall entail a bid specifying municipal tap -in fee, total length and cost per foot, location and permit. Connect to house supply lines, patch any unnecessary holes incurred where water line enters house, repair any necessary street damage, back fill and mound to allow settlement to previous ground level. Seeding or sodding the ground to match existing or blend in with the adjoining and surrounding work shall be at the discretion of the Grant Administrator. 7- Addition: -7- PLUMBING continued ❑ Provide Septic Sewage System - System shall be specified in the bid and include drawing. Installation shall include testing and permit costs. Connect t house drainage lines, provide reasonable protection to lawn, driveways, etc.* back fill and mound to allow settlement to previous ground level. Seeding or sodding the ground to match existing or blend in with the adjoining and surrounding work shall be at the discretion of the Grant Administrator. ❑ Addition: ❑ Provide Municipal Sewer - House connection to municipal sewer line shall entail a bid specifying municipal tap -in fee, total length of line and cost per foot, location and permit. Connect to house drainage lines, patch any unnecessary holes incurred where line enters house, repair any necessary street damage, fill existing septic tank(s) with dirt and back fill and mound to allow settlement to previous ground level. Seeding or sodding the ground to match existing or blend in with the adjoining and surrounding work. ❑ Addition: ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE STATE PLUMBING CODE 12. CEILINGS (See General Specification) ❑ Repair Ceiling in ❑ Kitchen ❑ Dining room ❑ Livingroom 13 Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement ❑ Basement ❑ Closet h 13. WALLS (See General Specification) Repair Wall in ❑ Kitchen ❑ Dining room [] Livingroom ® Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement ❑ Closet of Note: Tile falling off walls. -8- WALLS continued �X Wall and Ceiling Repair General Specification: 1. 'elherever existing walls or ceilings are to be repaired, the damaged and locse material shall be completely removed and new material shall be sized and installed to match and blend in with the adjoining and surrounding work. All repairs shall be properly prepared to receive the finish application. 2. Plastering - New plastering work shall be installed in compliance with the State Building Codes. 11 Board rd shall be installed in compliance with the State Building P codes. 4. Perforated Tape Mix - shall comply with the recommendations of the manufacturer. A minimum temperature of 55 degrees Fahrenheit shall be maintained in the room where work is done until the cement is completely dry. 5. Perforated Taoe Application - Follow manufacturer's directions. a. Over Joints the tape shall be embedded in cement and covered with a thin layer of cement. A second and third coat shall be applied. Each coat shall be dry before applying the next coat. Each coat shall be featheredged and extended beyond the previous coat (approximately 2 The finish coat shall be sanded lightly and any imperfections filled in prior to any painting and decorating. b. Check to see that all nails have been driven so that their heads are below the surface of the board leaving a dimple in the surface without breaking the paper. Cover the nails dimple with three applications of cement allowing time to dry between each coat. The final coat shall be sanded lightly before application of paint or other decoration. c. Inside corners shall be reinforced with tape embedded in cement finished as specified "Over Joints ". d. Outside corners shall be protected by wood moulding, metal moulding or metal corner reinforcement. Metal corner reinforcement shall be finished with two coats of cement as specified. 6. Waterproof gypsum board shall be used in areas specified in the State Building Code. Install water resistant wall board base in the bath and shower enclosure, and apply wall board with long edge horizontally over the tub, allowing 1/4" space between the board and tub. 7. Adhesive is an acceptable bonding material. Adhesive shall be specified according to usage and location and applied in strict compliance with the manufacturer's specifications. _a_ WALLS continued 8. Paneling installation shall be 3/16" prefinished paneling of a medium ua installed r q lity i lled as pe. manufacturer's recommendations. Owner shall have choice of paneling color and style. 9. Furring strips - New ceiling shall be installed over 1" x 3" furring strips, 12" on center. When ceiling butts to wood or paneled walls, 3/4" to 1 1/2 cove moulding shall be installed along edge. New wails shall be installed over 1" x 2" furring strips, 16 on center. Any existing baseboard, window or door trim shall be removed and reinstalled or replaced with new trim over new wall material, unless otherwise specified in the Scope of Improvements. New work shall be level and plumb with adjoining and surrounding work. Addition: 14. FINISH FLOORING Replace Floor Covering in Kitchen Diningroom Livingroom Bathroom Bedroom Bedroom Bedroom Bedroom Basement Closet of 1. Existing wood flooring shall be repaired to match existing or blend in with the adjoining and surrounding work. 2. Resilient flooring shall be sheet vinyl or vinyl asbestos tile minimum thickness 1/16 ". Tile shall be medium quality and laid in exact accordance with the manufacturer's specifications. Owner to select color and pattern from readily available selection. 3. Carpet shall be a color and pattern from readily available selection of medium quality and priced carpet. 4. A finished wood, vinyl or metal moulding along edge of flooring shall be installed as part of .he finish flccring installation. -1C- FLOORING continued 5. Plywood used as subfloor shall be a minimum of 1/2" thick, nailed to joist spaced 16" on center along intermediate members, installed with outer plies at right angles to the joists and staggered so the end joists in adjacent panels bear on different joists. 6. Underlayment shall be 1/4 structural grade plywood, particle board or untempered hard board placed with smooth side up. Addition: Replace floor covering in kitchen, bathroom and living room 15. EXTERIOR DOORS ❑ Repair and Refinish: ❑ Front Door ❑ Rear Door ❑ Side Door ❑ Garage Door ® Weather Seal: ❑ Front Door Rear Door ❑ Front Storm Door ❑ Rear Storm Door Replace: Front Door ❑ Rear Door ❑ Garage Door All exterior doors shall be solid core wood or insulated steel and complete with hardware, strike plat and lock set. Installed doors shall be prehung or sized to fit frame complete with stops, weatherstripping and jambs. After trimming and fitting of door, all edges shall be finished to match existing or blend in with the adjoining and surrounding work. A door bumper and threshold are included on all exterior doors. 16. EXTERIOR STORM DOOR OK ❑ Repair: ❑ Front Storm Door ❑ Side Storm Door ❑ Replace: ❑ Front Storm Door ❑ Side Storm Door Storm doors shall be solid core aluminum or wood with storm and screen inserts and complete with hardware and strike plate. Installed doors shall be sized to fit frame. All edges of wood storm shall be finished to match existing or blend in with the adjoining and surrounding work. -11- 17. INTERIOR BOORS k Repair Door to: ❑ Basement ❑ Bathroom FM Middle Bedroom Right Bedroom ® Left Bedroom Middle Bedroom ❑ Closet in Replace Door To: OK ❑ Basement ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Closet in Interior doors shall be hollow core or panel and complete with hardware and strike plate. Installed doors shall be prehung or sized to fit frame complete with stops and jambs. After trimming and fitting of door, all edges shall be finished to match existing or blend in with the adjoining and surrounding work. A door bumper is included on all interior doors. Bathroom door shall be provided with "privacy" lock set. ❑ Addition: -12- 18. EXTERIOR STORM AND SCREEN WINDOtdS ❑ Repair aj Replace [ Basement [KC Kitchen ❑ Diningroom Left 2 Ft Livingroom E] Bathroom 7X Middle Bedroom Right 2 [3 Right Bedroom Middle Bedroom1 Left Bedroom XX Second Bedroom Storm windows shall be aluminum combinations of medium quality, unless otherwise specified in the Scope of Improvements. 19. HOUSE WINDOWS [] Repair and Refinish Windows in: ❑ Basement ❑ Kitchen ❑ Diningroom ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom Repair of windows or replacements of frames s i ll s, s P , lls, ash, trim and hardware shall match existing work in wood, design, dimensions and finish, unless otherwise specified in the Scope of Improvements. Where sash counter balances are to be removed, the area must be insulated properly. Friction guides are acceptable as substitutes. Cotton cord replacement is acceptable. A positive locking device shall be installed on all windows. All broken glass shall be replaced with new glass, matching existing in size and design and properly reglazed. All excess material shall be removed and all glass left clean. Weather Seal Windows in: ❑ Kitchen ❑ Diningroom ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement Caulk and weatherstrip around all primary door and window frames, window panes or other locations that lead to an unheated space or which calls for a seal and watertight job. Materials shall be of standard brands and application shall be in exact accordance with the manufacturer's specifications. J Reolace Window in: ❑_ Kitchen ❑ Diningroom Livingroom 9E Bathroom ❑ Bedroom (❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement Openings of new window units shall be framed to provide a rigid enclosure for the installation of windows. Frames shall be set plumb, level and square within clearance limits. New windows shall match the adjacent windows in design, glass, material and finish, unless otherwise specified in the Scope of Improvements. Installed windows shall be weatherstripped, left clean, tight and weatherproof. ❑ A positive locking device shall be installed on all windows. ❑ Installed below grade bedroom window used as an excape exit shall have a opening size of not less than 5.7 sq. ft. with a minimum of 24" depth and 20" width. The interior sill height shall not be more than 48 from floor. Exterior of window shall be cleared for exit and when an areawell is installed it shall be of treated wood or galvanized metal. ❑ When a bedroom window unit is replaced, the new unit shall be sized to meet the requirements of the State Building Codes. U Addition: Replace bathroom window with glass block. Replace large window in living room. 20. INSULATION ❑ Insulate attic space to meet a minimum R -38 rating and have a vapor barrier, where accessible. Air chutes shall be installed where there is soffit venting. Provide protection around all recessed lights, junction boxes and chimney. Access opening shall be sized a minimum of 22" x 30 ", framed and insulated. ❑ Insulate exterior walls to a minimum of R -11. Drill holes and blow in insulation between wail studs approximately every 16" on center and below each fire stop. Holes shall be patched to match existing or blend with adjoining and surrounding work. ❑ Insulate exterior foundation with rigid insulation of R -11 to above grade and extend insulation 2' below grade and cover insulation with a non - combustible material. Foundation insulation shall be at the discretion of the Grant Administrator. -14- INSULATION continued ❑ Insulate accessible area rim joist to a minimum of R -19 with vapor barrier facing warm side. ❑ Addition: 21. VENTILATION ❑ Provide attic ventilation per Uniform Building Code as follows: Ventilation - where determined necessary by the building official due to atmospheric or climatic conditions, enclosed attics and enclosed rafter spaces formed where ceilings are applied direct to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain and snow. The net free ventilating area shall be not less than 1/150 of the area of the space ventilated, except that the area may be 1/300, provided at least 50% of the required ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least three feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents. The openings shall be covered with corrosion- resistant metal mesh with mesh openings of 1/4" in dimension. F Provide kitchen ventilation - Exhaust Fan - kitchen without means of natural or below minimum requirements of ventilation shall be equipped with a mechanical exhaust fan. Installation shall include mounting fan on ceiling, venting through the roof or exterior wall with cap, insulating vent in unheated space and wiring on a separate wall switch. ❑J Repair kitchen ventilation. r7 Provide bathroom ventilation - Exhaust Fan - Bathroom without means of natural or below minimum requirements of ventilation shall be equipped with a mechanical exhaust fan. Installation shall include mouting fan on ceiling, venting through the roof or exterior wall with cap, insulating vent in unheated space and wiring on a separate wall switch. ❑ Repair bathroom ventilation. ❑ Addition: -15- 22. EXTERIOR SIDING 7 Repair or replace all rotten boards and nail down all loose boards or shingles prior to receiving new siding. Side walls shall be furred out if necessary to make walls level, plumb and free from waves, buckles and sags. Installation shall be in strict compliance with the manufacturer's specifications. . 7 Existing brick work shall be repaired to match existing or blend in with the adjoining and surrounding work. 7 Reside exterior with .024 gauge, nominal thickness, insulated type aluminum of medium quality or equal. Color selection by owner. Installation shall include window J channel, door channel, inside and outside corners, starter strip, finish mould and caulking. Backing shall be installed under siding and be of proper thickness. All nails and rivets shall be properly secured. Staples shall not be used for installation. 1P Cover all window, door trim and sills with baked enamel aluminum, minimum .019 gauge. Color selection by owner. Lap - Siding shall be minimum 7/16" thick x 16 long, smooth, pre - primed masonite panels. Siding shall be installed with corrosion resistant nails and all ends shall be attached together with H- moulding and sealed with exterior caulking. Lap siding shall extend to 6 above finish grade. Novelty - Cover indicated sections of structure with new wood novelty siding, or other specified material. All joints shall be tight and adjacent end joints shall be staggered. Siding shall be installed over vapor barrier, blend and conform with existing structure. All horizontally applied siding shall be staggered with minimum of two stud spaces. M Cover soffit and fascia with .019 gauge baked enamel aluminum using solid or perforated soffit material. Color selection by owner. Soffit panels shall be secured in channels to eliminate looseness and rattling. Materials shall be lapped for proper drainage and applied in full sections. Caulk joints. Staples shall not be used for installation. Addition: -16- 23. PAINTING ' Repaint exterior siding, cornice, window and door trim including doors and windows as follows: Wood surfaces to be painted shall be cleaned by best means possible to remove loose and scaley paint and rough spots any any obvious oil and /or grease that may be covering existing wood or paint. Where previous coats have chipped and peeled, the .edge shall be feathered to the maximum extent feasible and spot primed with a high quality oil base paint before finish coats are applied. No paint shall be applied until all nail holes have been filled and sanded and all defects in wood work have been eliminated. Paint shall be medium grade and applied according to the manufacturer's specifications and applied to secure full coverage. Use primer where required. Owner to select color from readily available selection. Spray application is not acceptable, unless authorized by the Grant Administrator. Scrape and paint gutters. 24. GUTTERS AND DOWN SPOUTS ❑ Provide gutters and down spouts as follows: a) New gutters shall be minimum 5" wide .032 gauge aluminum with hangers placed under roofing. b) New downspouts shall be minimum 2" x 3" rectangular .020 gauge aluminum. c) Finish of gutters and downspouts shall be a baked on enamel finish. Owner to select color from readily available selection. d) Gutters shall be installed with slight pitch to the downspout. Gutters shall be securely mounted to the roof, 36" or less on center. Downspouts to be installed at one end of gutters and extend 2' at the bottom with extension. Extension or splash block shall be installed when the gutter and downspout system does not directly connect into a drainage system. ❑ Addition: 25. ROOFING pR r ❑ Provide new roof per City of Brooklyn Center Handout and as follows: New roofing shall be in compliance with the State Building Codes and Manufacturer's installation instructions. Flashing, plumbing jacks and roof vents shall be checked and replaced with new when damaged, rusted or missing. Drip edge shall be installed along eave edge. All damaged or rotted sheathing boards shall be replaced with new. End joints shall be made over a rafter and all sagging portions of roof shall be corrected. Materials - New roofing shall carry the Class C label of wind resistance from the Underwriter's Laboratories and be applied according to the manufacturer's specifications. The type and weight of the materials used for the roofing shall be in compliance with the State Building Codes. Application - Surfaces to which roofing is to be applied shall be even, sound, thoroughly clean, dry and free from all defects that might affect the quality of application. a) Asphalt Shingles - No more than one overlay of asphalt shingles shall be applied over an existing asphalt shingle roof. Shingles shall be fastened with not less than four nails or staples per shingle. Installed shingles shall be 235# - 240# 3 -tab self sealing. Roll roofing shall be installed when the slope is 4 or less. Owner to select color of shingles from readily available selection. b) Built -up - Existing roofing material shall be removed down to bare wood. New roofing shall be 4 -ply built -up tar and slag or gravel roof, including all new flashing of either metal or asphalt mineral roll material. Roof shall be installed in such a way that there is no ponding water. c) Wood Shingles and Shakes - Repair of existing roof shall match existing or blend in with the adjoining and surrounding ork an u a contractor g d include con r ctor for the repair work. d) Fiberglas - is an acceptable roofing material. ❑ T ear off existing roof and remove from site. ❑ Addition: -18- s 26. CHIMNEY NA ❑ Repair or replace missing brick. ❑ Tuck pointing shall be done only after the joints have been raked out to a minimum depth of 1/2" and wetted. ❑ Provide masonry chi=ey cap. ❑ Addition: 27. KITCHEN AND BATHROOM CABINETS ❑ Repair damaged kitchen cabinets. ❑ Repair damaged bathroom lavatory cabinet. ❑ Replace or add kitchen cabinets: New cabinets shall be described in complete detail, including design, dimension, installation and location of top or base units, detail of drawers, doors and shelves, type of material and finish in the Scope of Improvements. The contractor shall submit a drawing of the proposed cabinets. ❑ Replace bathroom lavatory cabinet: Vanity - lavatory base cabinet shall _ be medium quality. Top shall be approximately 22" wide with 3" back splash and covered with formica preformed or self edge top. Imitation moulded marble tops can be used as a substitute. ❑ Replace kitchen cabinet top: Kitchen Counter Top - shall be self edge or self forming formica with `t backsplash. Separate baeksplash material shall match formica counter top material. ❑ Replace bathroom lavatory vanity: Vanity - lavatory base cabinet shall be medium quality. Top shall be approximately 22" wide with 3 " back splash and covered with formica preformed or self edge top. Imitation moulded marble tops can be used as a substitute. ❑ Provide bathroom medicine cabinet: Cabinet - shall be standard size, recessed, or surface mounted, with a minimum of three shelves and mirror. When light fixture is included, fixture shall be wired on separate wall switch. -19- i 28 . SMOKE DETECTORS Install UL listed battery-operate manufacturer's F7 ery operated smoke detector per manufactur,.r s instructions without escape light complete with working batteries. 29. GRADING ❑ Provide grade fill as follows: ❑ Grade - Fill material shall be free of debris or other detrimental material. All fill shall be compacted to a density that will avoid damaging settlement to lot improvement. Top soil shall be a minimum of 4 compacted depth and free from stones, debris and other materials detrimental to plants. Slope away from building, 4 11 -6" over a distance of 3'-4' out from wall. Foundation walls shall extend at least 6" above the finished grade adjacent to the wall at all points. ❑ Seeding and Sodding as required. 30. EXTERIOR CONCRETE WORK ❑ Replace crumbled or broken sidewalks. ❑ Replace crumbled or broken garage entrance apron. 31. MISCELLANEOUS I. Check all downspouts on gutters. Repair or replace to keep water away from foundation. 2. Replace overhead garage door. 3. Trim all trees close to roof. UHC 888 V URBAN HENNEPIN COUNTY HOUSING REHABILITATION DEFERRED LOAN PROGRAM J rill A N' t�to HOMEOWNER APPLICATION FOR GRANT rAETRO KRA,. HOUSEHOLD INFORMATION -- Please Print First Name Name k of Spouse Address Home Phone City Zip Code?- ( Phone City of residence if other than mailing address Marital Status (check one) married, single, divorced, separated, widowed Race (check one) White, Black, American Indian /Native Alaskan, Hispanic, Asian or Pacific Islander The information concerning Minority Group Categories is requested for statistical purposed only so that Hennepin County may determine the degree to which its programs are utilized by Minority households. INCOME INFORMATION "Income" means any income received from any source by a Resident. List all the people in occupying your house for at least nine months of the year (including yourself). Include ages and incomes. Include any income derived from rent. Total number of residents in the household 7 A How many renters ? OFFICE USE ONLY `)3 v yo income of # in household names of ages of residents residents residents per month source of income verified incomes $ $ S Total Income $ �\� \� per month - $ ,,�1 l� per year $ �Z1� income per month RETURN APPLICATION TO: $ � S I Z a� Mr. Dale Ruedy (291 - 6596) Metro HRA income per year Mears Park Centre 230 East 5th Street St. Paul, MN 55101 A ASSET INFORMATION List the cash value of assets held by all residents of your household. If money is owed on any item, the value listed should equal the market value of the item minus the amount that is owed. OFFICE USE ONLY verified assets 1 . CASH on hand .......... ..............................$ $ 2. CASH in checking accounts ........................... $ )�� > $ S �'� .`1 1 �� - tj- 9 0 3. CASH in saving accounts (including those held ....... $ $ 6 J C 3 -f1-Sz in trust) 4. Cash value of Securities or U.S. Savings bonds...... $ $ 5. Redemption value of life insurance policies ......... $ $ 6. Current Market Value of real estate, NOT INCLUDING the property to be improved and up to 2 surrounding acres. Include 100% of the outstanding balance owed to you on property sold on Contract for Deed ... $ 7. Other personal property (excluding household furnishings, clothing and one personal vehicle) ..... $ $ TOTAL ASSETS .............. ..............................$ c �`i. ;(�_ $ S PROPERTY INFORMATION Provide the following information about the property to be improved with this deferred loan. 1. Is your property: -"�— a single family house; a duplex 2. How many years have you lived in the house? 3. What is the approximate age of the house? 4. Do you have any outstanding mortgage(s) on the house? X Yes No If yes, with whom? " r•, - r, c, (use additional sheet if necessary) Amount 5. Do you have any outstanding Contract(s) for Deed on the house? Yes No If yes, with whom? (use additional sheet if necessary) Amount $ 6. Have you received a Housing Rehabilitation Grant or Loan before? Yes No If yes, from whom? Amount $ Amount $ 2 1' PLEASE READ CAREFULLY Urban Hennepin County or an authorized representative shall have the right to inspect the property to be improved at any time from the date of the Deferred Loan upon given due notice to the occupant(s). An person who makes a false statement or misrepresentation in connection with the Y P p application for or use of Urban Hennepin County Deferred Loan funds shall be subject to a fine or imprisonment, or both, under the provisions of the Minnesota Criminal Code, and /or may be required to return all or part of the Deferred Loan Funds to Urban Hennepin County. I, the undersigned, certify subject to penalty under law that the above information is true and correct to the best of my knowledge and belief, and that the provisions stated are accepted and agreed to. �\ applicant signature < date of application Note: All names and financial information provided on this application are considered private data on individuals and are subject to privacy of information provisions, pursuant to State Statute. 3 MEMORANDUM TO: Tom Bublitz, Assistant EDA Coordinator FROM: Dave Fisher, Building Inspector DATE: June 15, 1992 SUBJECT: Rehabilitation Grant for 5401 Fremont Avenue North Homeowner: Patti Jo Breuninger H -105 (8031) Subject property is a two bedroom, 1 1/4 story, approximately 69 years old. The major deficiencies noted: Old abandoned well, old dilapidated siding and drafty windows. The following list of rehabilitation items would improve this home greatly: Mechanical 1. Provide cold air register in upper level. Plumbing 1. Cap abandoned well to code. Miscellaneous 1. Install handrail on basement stairs, upper level stairs and front steps. 2. Install guardrail to code by back door. 3. Replace steps at back entry to code. 4. Repair foundation in basement by patching and sealing. 5. Repair ceiling in kitchen and by entry. 6. Repair walls in kitchen and by entry. 7. Replace missing moulding throughout house (kitchen, entry, living room, porch and bedrooms). Also around doors and windows. 8. Replace floor covering in kitchen, back entry and upper level bedroom. Memorandum, Page Two 6 -15 -92 Breuninger 9. Replace front exterior door on house. 10. Replace garage service door. 11. Replace front storm door. 12. Replace door to main level bedroom. 13. Replace bedroom window on main floor to code. (Must meet egress requirements). 14. Replace two (2) windows by entry in to kitchen. 15. Replace window in bathroom. 16. Replace ten (10) windows on porch. Replace sash only on the window in porch. 17. Insulate around exterior foundation. 18. Insulate around rim joist to R -19. 19. Provide attic ventilation to code. 20. Provide kitchen exhaust fan. 21. Reside house and paint garage to match. 22. Provide gutters and downspouts. 23. Tear off roof and reroof house and garage. 24. Seed and sod as required around back entry. 25. Replace crumbled sidewalk. URBAN HENNEPIN COUNTY HOUSING REHABILITATION GRANT PROGRAM PROPERTY INSPECTION REQUEST TO COUNCIL: Tune 22, 1992 H -105 (80311 APPLICANT INSPECTION Name Patti Jo Breuninger Staff Tom Bublitz Address 5401 Fremont Avenue North Date June 4, 1992 Brooklyn Center, MN 55430 Time 2:00 P.M. Phone 560 -3849 (h) 557 -4106 (w) Inspector David Fisher Building Age: 69 years Garage: Detached TABLE OF CONTENTS ART - PAGE 401 ❑% HANDRAIL - GUARDRAIL: $ 1 Where required, Height of, Baluster Spacing and Installation, Specification for 2 INTERIOR - EXTERIOR STAIRS $ 1 Repair or Replacement of, Rise and Run and Installation, Specification for 3 ® FOUNDATION $ 2 Repair of —Tuck Pointing Insulation Installation and Specification for 14 4 Q CRAWL SPACE: $ 2 Insulation of and Vapor Barrier, Installation for 5 ❑ BASEMENT FLOOR $ 2 Repair of 6 ❑ POST AND BEAM: $ 3 Repair of, Replace 7 ❑ ACCESSIBILITY IMPROVEMENT $ 3 For Barrier Free and Handicapped Persons 108 ❑ ELECTRICAL $ 3 Upgrade Service, Unprotected Conductor,Washer, Dryer, Hanging Receptacle, Furnace and Kitchen Circuits Wall Receptacle, Ground Fault 4 9 ❑ ELECTRICAL MAST: $ 4 Relocation of 10 MECHANICAL $ 4 Enclosed Space Ventilation, Replace Furnace Thermostat, Chimney, Registers, Ductwork 11 PLUMBING: $ 5 Water Heater Replacement, Cold Water Shut -off, Gas Valve T.P.R. Valve, Vent Connector, Dryer Gas Valve, Dryer 6 - Ventilation, Open Gas Device,Well Abandonment, Plugged Sewer, Water Softener, Kitchen Sink Vent, Trap, Water Supply, Lavatory Vent, Trap, Water Supply, Water Closet and Sealing Gasket, Bathtub Vent, Trap, Wall Enclosure, Laundry Tub Vent, Trap, Floor Drain Plumbing Fixture Material and Performance Specifications 7 for, Drain Tile, Main Water Line Septic System, City Sewer 8 -1- TABLE OF CONTENTS PART r PAC 1 012 CEILINGS $ E Repair of 13 WALLS: $ F Repair of 13 Ceiling and Wall Performance and Material Specifications for 9 -1 14 FINISH FLOORS $ 10 -1 Replacement of, Performance and Material Specifications for 15 [X EXTERIOR DOORS: $ 1 Repair - Refinish of, Weather Sealing, and Replacement of, Performance Specification for 16 ( EXTERIOR STORM DOORS: $ 1 Repair - Replacement of, Material Specification for 17 INTERIOR DOORS $ 1 Repair - Replacement of, Performance and Material Specifications for 18 ❑ EXTERIOR STORM AND SCREEN WINDO! %'S: $ 1 Repair - Replacement of, Material Specification for 1 09 ® HOUSE WINDOWS: _ $ 13-1 Repair - Refinish of, Weather Sealing of, Replacement of, Material and Performance Specification for 20 ® INSULATION: $ 14 -1 Attic, Wall, Foundation, Rim Joist Installation, Material and Performance Specification for, Code Requirement 21 ( VENTILATION: $ 1 Provision of Attic, Kitchen, Bathroom, Repair of, Material and Performance Specification for 22 [ EXTERIOR SIDING: $ 1 Installation, Repair or Replacement of, Soffit and Facia, Window, Door and Cornice Trim, Material and Performance Specification for 23 ( EXTERIOR PAINTING: $ 1, MateriaT Performance Specification for 24 GUTTERS AND DOWNSPOUTS: $ 1' Provision for an Replacement of, Material and Performance Specification for ® ROOFING: $ 1, Repair - Replacement - Removal of, Material and Performance Specification for -2- TABLE OF CONTENTS PART - PAGE 26 CHIMNEY Repair - Reline - Replacement of $ 5 -19 i 27 F"I KITCHEN & BATHROOM CABINETS $ lg 28 Q SMOKE DETECTORS installation of $ 20 29 GRADING Material and Placement Specification for, Seeding and $ 20 Sodding of 30 EXTERIOR CONCRETE WORK Replacement - Repair of, Sidewalks, Garage Apron, Etc. $ 20 31 F7 MISCELLANEOUS: $ 20 TOTAL Contractor Name: Address: City State Phone: Home Work Homeowner Name: Patti Jo Breuninger Address: 5401 Fremont Avenue North (55430) Phone: 560 -3849 (h) 557 -4106 (w) H# 105 (8031) Contractor Signature Date -3- 1. INSTALL HANDRAIL: (outside) [ Basement Stair Front Stair ❑ Rear Stair Upper Level Stair One handrail shall be installed on stairways 44" or less in width, except that stairways open on one or both sides shall have handrails provided on the open side or sides. Handrails shall not be less than 30 nor more than 34" in height above stair tread. Unenclosed floor, open landings and ramps at a height of over 30 from floor or grade shall have a guardrail. Guardrail shall not be less than 36" in height and shall have intermediate rails or an ornamental pattern such that a sphere 6 in diameter cannot pass through. Materials and finish shall be specified in the Scope of Improvements and installation shall be in compliance with the State Building Codes. ® Addition: Wood guard rail required to match existing on interior. Install guard rail to code by back door. 2. INTERIOR _ EXTERIOR STAIRS ❑ Repair ❑ Basement ❑ Second Storey ❑ Front ❑ Rear Entrance Stairs ❑ Replace ❑ Basement [] Second Storey ❑ Front Rear Entrance Stairs Stair riser to be a minimum of 4 to a maximum of 7 " high. Stair tread to be a minimum of 11" wide. Wood stair stringer shall be of 2 x 10 nominal stock. Exterior stairs can be of treated stock or concrete having footings 42" minimum below grade. ® Addition: Step may be required with landing. -1- 3. REPAIR FOUNDATION: ® All joints shall be completely filled with mortar. ❑ Tuck pointing shall be done only after the joints have been raked out to a minimum depth of 1/2" and wetted. Addition: Repair all p basement walls by patching and sealing. 4. CRAi I SPACE: N /A: ❑ Either insulate perimeter foundation wall to R -11 or floor to a minimum of R -19. A 6 mil. polyethylene plastic vapor barrier shall be installed over dirt area and be weighted by sand, rocks or other non -wood materials. ❑ Addition: 5• BASEKENT FLOOR: OK ❑ Patch holes and large cracks. ❑ Addition: i it -2- 6. POST AND BEAM OK ❑ Repair or replace as marked. ❑ Addition: 7. ACCESSIBILITY IMPROVEMENTS N/A ❑ Refer to Minnesota State Building Code Chapter 55 for accessibility architecture specifications. The type and scope of accessibility improvements shall be at the discretion of the Grant Administrator. ❑ Addition: 8. ELECTRICAL: OK ❑ Install new U.L. certified 100 amp service panel and circuit breakers. ❑ Relocate unprotected plastic coated conductors to center of wood joist or in metal protective tubing located in ❑ Provide grounded receptacle for: ❑ Washer & Dryer on a separate 20 amp circuit. ❑ Water Softner. ❑ Other ❑ Replace hanging light or receptacle with porcelain fixture mounted on an approved box and properly grounded. ❑ Provide separate 15 amp circuit to furnace. ❑ Provide separate 20 amp circuit to kitchen countertop work area receptacles. -3- ELECTRICAL COUINUED OK ❑ Add wall receptacle in: kitchen; ❑ in dining room; ❑ bedroom ❑ bedroom ❑ bedroom ❑ bedroom ❑ living room ❑ bathroom ❑ with ❑ without ground fault. ❑ laundry room ❑ Addition: 9. ELECTRICAL MAST; OK ❑ Relocate ❑ Other ❑ Addition: ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE TO THE NATIONAL ELECTRICAL CODE. 10. MECHANICAL: 4 ❑ Provide ventilation of enclosed furnace space. ❑ Provide heat loss calculation of dwelling and install new heating manufacturer's instructions capable to meet the heat loss. The minimum AFUE shall be listed at 804 and shall include damper efficiency. New appliance shall be AGA or UL listed and orsat tested. -4- ❑ Replace gas valve with approved lever handle gas valve or ball valve ❑ Replace vent connector from furnace to chimney with 26 gauge galv. sheet metal vent materials. ❑ Provide combustion air ❑ Provide set back thermostat. ❑ Reline existing Class B Chimney to expel water heater or other gas appliance combustion gases if new heating appliance is vented through the side wall. ❑ Remove ❑ Reline existing Class B Asbestos Chimney. ❑ Add warm air register in Add return air register in Upper Level ❑ Add Duct work _ ❑ Addition: i ALL MECHANICAL WORK SHALL BE IN COMPLIANCE WITH STATE IECHANICAL CODES. 11. PLUMBING .S ❑ Install new gallon energy miser water heater having AGA or UL listing complete with necessary gas piping tested for leaks, new lever handle gas valve or ball valve, new vent connector sealed and secured at all joints, new temperature pressure relief valve with 3/4" overflow tube extending to 6 " above finished floor. Water heater shall be warranted for five years. ❑ Install cold water shut off valve on existing water heater. ❑ Install approved gas valve on existing water heater. PLUMBING continued ❑ Install temp., pressure, relief valve on existing water heater. Q Install new vent connector on existing water heater. F Install new approved gas valve on gas dryer. ❑ Vent gas dryer to outside air. ❑ Plug or cap open gas valve or fitting located at or near Disconnect existing well water and reconnect water service to City water with meter and reconnect electrical ground to City side of water meter. Well to be properly abandoned, inspected and approved by the State Health Department or City Sanitarian. Q Rout out main house sewer and clear stoppage. ❑ Repair or replace inoperable water softener. ❑ Install new kitchen sink vented to outside air. ❑ Install new kitchen sink water supply tubes and valves. ❑ Install new kitchen sink trap. . ❑ Install new lavatory sink vented to outside air. ❑ Install new bathroom lavatory water supply tubes and valves. ❑ Install new bathroom lavatory trap. Q Install new bathroom water closet complete with seat and shut off valve. ❑ Install new water closet setting seal gasket. ❑ Install new bathtub vented to outside air. ❑ Install new bathtub waste trap. ❑ Install new bathtub wall enclosure and shower curtain rod. ❑ Install new laundry tub vented to outside air. ❑ Install new laundry tub waste trap. ❑ Floor Drain ❑ Inoperable ❑ Install Other Cap abandoned well. -6- PLUMBING continued ' ❑ 'New kitchen sink shall be 33" x 22 self- rimming, unless otherwise specified in the Scope of Improvements. Sink shall be stainless steel or cast iron and faucets shall be either single lever or two handle. a. Garbage disposal is only an acceptable work item in these two circumstances. ❑ 1. reinstallation of existing disposal when installing a new sink. ❑ 2. removing and disposal. Q New bathtub shall be cast iron, fiberglas or steel. Faucets shall either be single lever or two handle. Color selection shall be limited white unless specified to match existing color. Installation of a fiberglas tub insert is at the discretion of the Grant Administrator. ❑ New lavatory shall be wall -hung or with vanity. Trap shall be .17 gauge. Color selection shall be limited to white unless specified to match existing color. Refer to Carpentry section for dabinet specification. ❑ New water closet shall be viterous china with close coupled tank, include seat and anti - siphon ballcock. Color selection shall be limited to white unless specified to match existing color. ❑ New laundry tub shall be fiberglas and securely attached to wall or free standing. Faucet shall be stainless steel or brass type and nonthreaded or with a vacuum breaker. Q Provide basement interior perimeter wall drain tile system and floor sump pump. Sump pump shall discharge to an exterior french drain or City storm sewer. French drain shall be located a minimum of ft. from foundation wall and be filled with a minimum of cubic feet of 3/4" stone. Stone shall be topped with sod or reseeded to match existing landscape. ❑ Addition: Q Provide Vunicipal Water - House connection to municipal water line shall entail a bid specifying municipal tap -in fee, total length and cost per foot, location and permit. Connect to house supply lines, patch any unnecessary holes incurred where water line enters house, repair any necessary street damage, back fill and mound to allow settlement to previous ground level. Seeding or sodding the ground to match existing or blend in with the adjoining and surrounding work shall be at the discretion of the Grant Administrator. Q Addition: -7- PLUMBING continued ❑ Provide Seotic Sewage System - System shall be specified in the bid and include drawing. installation shall include testing and permit costs. Connect to house drainage lines, provide reasonable protection to lawn, driveways, etc . back fill and mound to allow settlement to previous ground level. Seeding or , sodding the ground to match existing or blend in with the adjoining and surrounding work shall be at the discretion of the Grant Administrator. ❑ Addition: ❑ Provide Municipal Sewer - House connection to municipal sewer line shall entail a bid specifying municipal tap -in fee, total length of line and cost per foot, location and permit. Connect to house drainage lines, patch any unnecessary holes incurred where line enters house, repair any necessary street damage, fill existing septic tank(s) with dirt and back fill and mound to allow settlement to previous ground level. Seeding or sodding the ground to match existing or blend in with the adjoining and surrounding work. ❑ Addition: ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE STATE PLUMBING CODE 12. CEILINGS (See General Specification) 9]X Repair Ceiling in g Kitchen ❑ Dining room ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement ❑ Entry ❑ Basement Tape and finish 13. WALLS (See General Specification) Repair Wall in E Kitchen [] Dining room ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom 1:1 Bedroom Basement Entry ❑ Tape and finish -8- 14ALLS continued ',-,'all and Ceiling Repair Ceneral Specification: 1. Wherever existing walls or ceilings are to be repaired, the damaged and loose material shall be completely removed and new material shall be sized and installed to match and blend in with.the adjoining and surrounding work. All repairs shall be properly prepared to receive the finish application. 2. Plastering - New plastering work shall be installed in compliance with the State Building Codes. 3. 61all Board - shall be installed in compliance with the State Building codes. 4. Perforated Tape Mix - shall comply with the recommendations of the manufacturer. A minimum temperature of 55 degrees Fahrenheit shall be maintained in the room where work is done until the cement is completely dry. 5. Perforated Tape Application - Follow manufacturer's directions. a. Over Joints the tape shall be embedded in cement and covered with a thin layer of cement. A second and third coat shall be applied. Each coat shall be dry before applying the next coat. Each coat shall be featheredged and extended beyond the previous coat (approximately 2 The finish coat shall be sanded lightly and any imperfections filled in prior to any painting and decorating. b. Check to see that all nails have been driven so that their heads are below the surface of the board leaving a dimple in the surface without breaking the paper. Cover the nails dimple with three applications of cement allowing time to dry between each coat. The final coat shall be sanded lightly before application of paint or other decoration. c. Inside corners shall be reinforced with tape embedded in cement finished as specified "Over Joints ". d. Outside corners shall be protected by wood moulding, metal moulding or metal corner reinforcement. Metal corner reinforcement shall be finished with two coats of cement as specified. 6. Waterproof gypsum board shall be used in areas specified in the State Building Code. Inotall water resistant wall board base in the bath and shower enclosure, and apply wall board with long edge horizontally over the tub, allowing 1/4 space between the board and tub. 7. Adhesive is an acceptable bonding material. Adhesive shall be specified according to usage and location and applied in strict compliance with the manufacturer's specifications. -9- WALLS continued 8. PanelinL7 installation shall be 3/16" prefinished paneling of a medium quality installed as per manufacturer's recommendations. Owner shall have choice of paneling color and style. 9. Furring strips - New ceiling shall be installed over 1 x 3 " furring strips, 12" on center. When ceiling butts to wood or paneled walls, 3/4 to 1 1/2" cove moulding shall be installed along edge. New walls shall be installed over 1" x 2 furring strips, 16" on center. Any existing baseboard, window or door trim shall be removed and reinstalled or replaced with new trim over new wall material, unless otherwise specified in the Scope of Improvements. New work shall be level and plumb with adjoining and surrounding work. Addition: Install new moulding throughout house. Kitchen, entry, living room, porch, bedrooms On floor and around windows and door. 14. FINISH FLOORING Replace Floor Covering in (Kitchen Diningroom Livingroom Bathroom Bedroom Upper Level Bedroom Bedroom Bedroom Basement Closet of Entry area. 1. Existing wood flooring shall be repaired to match existing or blend in with the adjoining and surrounding work. 2. Resilient flooring shall be sheet vinyl or vinyl asbestos tile minimum thickness 1/16 Tile shall be medium quality and laid in exact accordance with the manufacturer's specifications. Owner to select color and pattern from readily available selection. 3• Carpet shall be a color and pattern from readily available selection of medium quality and priced carpet. 4. A finished wood, vinyl or metal moulding along edge of flooring shall be installed as part of the finish flooring installation. -10- FLOORING continued 5. Plywood used as subfloor shall be a minimum of 172" thick, nailed to ' Joist spaced 16" on center along intermediate members, installed with outer plies at right angles to the joists and staggered so the end joists in adjacent panels bear on different joists. 6. Underlayment shall be 1/4" structural grade plywood, particle board or untempered hard board placed with smooth side up. ❑ Addition: 15• EXTERIOR DOORS ❑ Repair and Refinish: ❑ Front Door ❑ Rear Door ❑ Side Door ❑ Garage Door ❑ Weather Seal: ❑ Front Door ❑ Rear Door ❑ Front Storm Door ❑ Rear Storm Door Replace: ® Front Door ❑ Rear Door aj Garage Door All exterior doors shall be solid core wood or insulated steel and complete with hardware, strike plat and lock set. Installed doors shall be prehung or sized to fit frame complete with stops, weatherstripping and jambs. After trimming and fitting of door, all edges shall be finished to match existing or blend in with the adjoining and surrounding work. A door bumper and threshold are included on all exterior doors. 16. EXTERIOR STORM DOOR ❑ Repair: ❑ Front Storm Door ❑ Side Storm Door ® Replace: ® Front Storm Door ❑ Side Storm Door Storm doors shall be solid core aluminum or wood with storm and screen inserts and complete with hardware and strike plate. Installed doors shall be sized to fit frame. All edges of wood storm shall be finished to match existing or blend in with the adjoining and surrounding work. -11- 17. INTERIOR BCORS ❑ Repair Door to: ❑ Basement ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Closet in Replace Door To: ❑ Basement ❑ Bathroom ® Main Level Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Closet in Interior doors shall be hollow core or panel and complete with hardware anal strike plate. Installed doors shall be prehung or sized to fit frame complete with stops and jambs. After trimming and fitting of door, all edges shall be finished to match existing or blend in with the adjoining and surrounding work. A door bumper is included on all interior doors. Bathroom door shall be provided with "privacy" lock set. ❑ Addition: -12- 18. EXTERIOR STORM AND SCREEN WINDOWS ❑ Repair ❑ Replace ❑ Basement ❑ {,itchen ❑ Diningroom ❑ Livingroom ❑ Bathroom ❑ Bedroom [] _Bedroom [] Bedroom ❑ Bedroom Storm windows shall be aluminum combinations of medium quality, unless otherwise specified in the Scope of Improvements. 19. HOUSE WINDOWS ❑ Repair and Refinish Windows in: ❑ Basement ❑ Kitchen ❑ Diningroom ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom Repair of windows or replacements of frames, sills, sash, trim and hardware shall match existing work in wood, design, dimensions and finish, unless otherwise specified in the Scope of Improvements. Where sash counter balances are to be removed, the area must be insulated properly. Friction guides are acceptable as substitutes. Cotton cord replacement is acceptable. A positive locking device shall be installed on all windows. All broken glass shall be replaced with new glass, matching existing in size and design and properly reglazed. All excess material shall be removed and all glass left clean. Weather Seal Windows in: ❑ Kitchen ❑ Diningroom ❑ Livingroom ❑ Bathroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Bedroom ❑ Basement Caulk and weatherstrip around all primary door and window frames, window panes or other locations that lead to an unheated space or which calls for a seal and watertight job. Materials shall be of standard brands and application shall be in exact accordance with the manufacturer's specifications. -13- (By 2 Entry) NA OK 1 Reolace Window in: 9 Kitchen ❑ Diningroom ❑ LJvingroom � Bathroom 1 Main Bedroom RYjbn= (Porch - 10 windows) ❑ Bedroom ❑ Bedroom ❑ Basement Openings of new window units shall be framed to provide a rigid enclosure for the installation of windows. Frames shall be set plumb, level and square within clearance limits. New windows shall match the adjacent windows in design, glass, material and finish, unless otherwise specified in the Scope of Improvements. Installed windows shall be weatherstripped, left clean, tight and weatherproof. ® A positive locking device shall be installed on all windows. ❑ Installed below grade bedroom window used as an excape exit shall have a opening size of not less than 5.7 sq. ft. with a minimum of 24" depth and 20" width. The interior sill height shall not be more than 48" from floor. Exterior of window shall be cleared for exit and when an areawell is installed it shall be of treated wood or galvanized metal. iff When a bedroom window unit is replaced, the new unit shall be sized to meet the requirements of the State Building Codes. Addition: Bedroom window must meet 5.7 sg ft egress and 101 floor area State requirement (Replace to match New windows) 20. INSULATION OK ❑ Insulate attic space to meet a minimum R -38 rating and have a vapor barrier, where accessible. Air chutes shall be installed where there is soffit venting. Provide protection around all recessed lights, junction boxes and chimney. Access opening shall be sized a minimum of 22" x 30 ", framed and insulated. OK ❑ Insulate exterior walls to a minimum of R -11. Drill holes and blow in insulation between wall studs approximately every 16 on center and below each fire stop. Holes shall be patched to match existing or blend with adjoining and surrounding work. U Insulate exterior foundation with rigid insulation of R -11 to above grade and extend insulation 2' below grade and cover insulation with a non - combustible material. Foundation insulation shall be at the diocretion of the Grant Administrator. -14- INSULATION continued ® Insulate accessible area rim joist to a minimum of R -i9 with Bracer barrier facing warm side. - Addition: 21. VENTILATICN M Provide attic ventilation per Uniform Building Code as follows: Ventilation - where determined necessary o ry b the building official due � Y g atmospheric or climatic conditions, enclosed attics and enclosed rafter spaces formed where ceilings are applied direct to the underside of roof rafters shall have cross ventilation for each seoarate space b ventilating P against P ve la in openi s rotected a • Y g P o P g the entrance of rain and snow. The net free ventilating area shall be not less than 1/150 of the area of the space ce ventilated except that the area may be 1 P , Y /300, provided at least 50" of the required ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least three feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents. The openings shall be covered with corrosion- resistant metal mesh with mesh openings of 1/4" in dimension. ® Provide kitchen ventilation - Exhaust Fan - kitchen without means of natural or below minimum requirements of ventilation shall be equipped with a mechanical exhaust fan. Installation shall include mounting fan on ceiling, venting through the roof or exterior wall with cap, insulating vent in unheated space and wiring on a separate wall switch. Q Repair kitchen ventilation. Provide bathroom ventilation - Exhaust Fan - Bathroom without means of natural or below minimum requirements of ventilation shall be equipped with a mechanical exhaust fan. Installation shall include mouting fan on ceiling, venting through the roof or exterior wall with cap, insulating vent in unheated space and wiring on a separate wall switch. [� Repair bathroom ventilation. [ Addition: -15- 22. EXTERIOR SIDING . Repair or replace rot ten � board F1 p ac.. all _ �t�en boards and nail down all loose b�ar,.� c- .r shingles les riot to receiving w � w new siding. Side wails shall g P 11 all be furred out if necessary � � f to make walls level, plumb and free from waves, buckles and sags. Installation shall be in strict compliance with the manufacturer's specifications. . F� Existing brick work shall be repaired to match existing or blend in with the adjoining and surrounding work. Reside exterior with .024 gauge, nominal thickness, insulated type aluminum of medium quality or equal. Color selection by owner. Installation shall include window J channel, door channel, inside and outside corners, starter strip, finish mould and caulking. Backing shall be installed under siding and be of proper thickness. All nails and rivets shall be properly secured. Staples shall not be used for installation. I Cover all window, door trim w'` 9 , m and sills with baked enamel aluminum minimum .019 gauge. Color selection by owner. Lap - Siding shall be minimum 7/16" thick x 16 long, smooth, pre - primed masonite panels. Siding shall be installed with corrosion resistant nails and all ends shall be attached together with H- moulding and sealed with exterior caulking. Lap siding shall extend to 6 above finish grade. Novelty - Cover indicated sections of structure with new wood novelty siding, or other specified material. All joints shall be tight and adjacent end joints shall be staggered. Siding shall be installed over vapor barrier, blend and conform with existing structure. All horizontally applied siding shall be staggered with minimum of two stud spaces. fil Cover soffit and fascia with .019 gauge baked enamel aluminum using solid or perforated soffit material. Color selection by owner. Soffit panels shall be secured in channels to eliminate looseness and rattling. Materials shall be lapped for proper drainage and applied in full sections. Caulk joints. Staples shall not be used for installation. Addition: -16- 23. PAINTING Repaint exterior siding, cornice, window and door trim including doors and windows as follows: Wood surfaces to be painted shall be cleaned by best means possible to remove loose and scaley paint and rough spots any any obvious oil and /or grease that may be covering existing wood or paint. Where previous coats have chipped and peeled, the edge shall be feathered to the maximum extent feasible and spot primed with a high quality oil base paint before finish coats are applied. No paint shall be applied until all nail holes have been filled and sanded and all defects in wood work have been eliminated. Paint shall be medium grade and applied according to the manufacturer's specifications and applied to secure full coverage. Use primer where required. Owner to select color from readily available selection. Spray application is not acceptable, unless authorized by the Grant Administrator. (Garage to match) 24. GUTTERS AND DOWN SPOUTS Provide gutters and down spouts as follows: a) New gutters shall be minimum 5 wide .032 gauge aluminum with hangers placed under roofing. b) New downspouts shall be minimum 2 x 3" rectangular .020 gauge aluminum. C) Finish of gutters and downspouts shall be a baked on enamel finish. Owner to select color from readily available selection. d) Gutters shall be installed with slight pitch to the downspout. Gutters shall be securely mounted to the roof, 36" or less on center. Downspouts to be installed at one end of gutters and extend 2' at the bottom with extension. Extension or splash block shall be installed when the gutter and downspout system does not directly connect into a drainage system. ❑ Addition: -17- 25. RCCFINO Provide rew roof per City of Brooklyn Center Handout and as follows: New roofing shall be in compliance with the State Building Codes and anufacturer's installation instructions. Flashing, plumbing jacks and roof vents shall be checked c ed and replaced d w' P ith new when damaged, rusted or missing. Drip edge g shall 0 1 be installed along eave edge. All damaged or rotted sheathing boards shall be replaced p ced with new. End joints shall be made over a rafter and all sagging portions of roof shall be corrected. Materials - New roofing shall carry the Class C label of wind resistance from the Underwriter's Laboratories and be applied according to the manufacturer's specifications. The type and weight of the materials used for the roofing shall be in compliance with the State Building Codes. Application - Surfaces to which roofing is to be applied shall be even, sound, thoroughly clean, dry and free from all defects that might affect the quality of application. a) Asphalt Shingles - No more than one overlay of asphalt shingles les sha 1 g 1 be applied ,pl ed over an existing asphalt shingle roof. Shingles shall be fastened with not less than four nails or staples per shingle. Installed shingles shall be 235# - 240# 3 -tab self sealing. Roll roofing shall be installed when the slope is 4 or less. Owner to select color of shingles from readily available selection. b) Built -up - Existing roofing material shall be removed down to bare wood. New roofing shall be 4 -ply built -up tar and slag or gravel roof, including all new flashing of either metal or asphalt mineral roll material. Roof shall be installed in such a way that there is no ponding water. c) Wood Shingles and Shakes - Repair of existing roof shall match existing or blend in with the adjoining and surrounding work and include a contractor warranty for the repair work. d) Fiberglas - is an acceptable roofing material. Tear off existing roof and remove from site. ]Addition: Garage and house -18- 25. CHIi21EY NA ❑ Repair or replace missing brick. ❑ Tuck pointing shall be done only after the joints have been raked out to a minimum depth of 1/2" and :netted. ❑ Provide masonry chimney cap. ❑ Addition: 27. KITC=N AND BATHRCCM CABI.IETS ❑ Repair damaged kitchen cabinets. OK ❑ Repair damaged bathroom lavatory cabinet. ❑ Replace or add kitchen cabinets: New cabinets shall be described in complete detail, including design, dimension, installation and location of top or base units, detail of drawers, doors and shelves, type of material and finish in the Scope of Improvements. The contractor shall submit a drawing of the proposed cabinets. ❑ Replace bathroom lavatory cabinet: Vanity - lavatory base cabinet shall _ be medium quality. Top shall be approximately 22" wide with 3" back so lash and covered with formica preformed or self edge top. Imitation moulded marble tops can be used as a substitute. ❑ Replace kitchen cabinet top: Kitchen Counter Top - shall be self edge or self forming formica with U backsplash. Separate backsplash material shall match formica counter top material. ❑ Replace bathroom lavatory vanity: Vanity -lavatory base cabinet shall be medium quality. Top shall be approximately 22" wide with 3" back splash and covered with formica preformed or self edge top. Imitation moulded marble tops can be used as a substitute. ❑ Provide bathroom medicine cabinet: Cabinet - shall be standard size, recessed, or surface mounted, with a minimum of three shelves and mirror. 'When light fixture is included, fixture shall be wired on separate wall switch. -19- 28. SMICKE DETECTORS OK , ❑ install UL listed battery - operated smoke detector per manufacturer's instructions without escape light complete with working batteries. 29. GRADING [f Provide grade fill as follows: OK Grade - Fill material shall be free of debris or other detrimental material. All fill shall be compacted to a density that will avoid damaging settlement to lot improvement. Top soil shall be a minimum of 4 compacted depth and free from stones, debris and other materials detrimental to plants. Slope away from building, 4 11 -6" over a distance of 3'-4' out from wall. Foundation walls shall extend at least 6" above the finished grade adjacent to the wall at all points. X Seeding and Sodding as required. 30. EXTERIOR CONCRETE WORK (d Replace crumbled or broken sidewalks. [� Replace crumbled or broken garage entrance apron. 31. PIIISCELLANEOUS