Loading...
HomeMy WebLinkAbout1995 03-16 PCP PLANNING COMMISSION AGENDA CITY OF BROOKLYN CENTER MARCH 16, 1995 REGULAR SESSION 1. Call to Order: 7:30 p.m. 2. Roll Call 3. Approval of Minutes - March 2, 1995 4. Chairperson's Explanation The Planning Commission is an advisory body. One of the Commission's functions is to hold public hearings. In the matters concerned in these hearings, the Commission makes recommendations to the City Council. The City Council makes all final decisions in these matters. 5. Brookdale Office Park Partnership 95003 Special Use Permit amendment to allow an expansion of the Cardinal Strich College operation located in the Brooklyn Crossing Office Building, 3300 County Road 10. • 6. VenStar Corporation 95004 Site and Building Plan approval for a 60,090 sq. ft. building for General Litho Services, Inc. to be located west of Parkway Circle, north of the Holiday Inn. 7. Other Business 8. Adjournment • .. Y i Planning Commission Information Sheet Application No. 95003 Applicant: Brookdale Office Park Partnership Location: 3300 County Road 10 Request: Special Use Permit Amendment (92015) The applicant, Brookdale Office Park Partnership, requests an amendment to the Special Use Permit granted in December, 1992 (Planning Commission Application No. 92015) on behalf of Cardinal Strich College to operate an educational use in the five story office building located at.3300 County Road 10. The amendment would involve providing two additional classrooms and a student lounge to the existing three classrooms currently comprising the Cardinal Strich operation which occupies a portion of the fourth floor in the Brookdale Crossing office building. The property in question is zoned C-IA (service/office) and is bounded on the north by single family homes, on the east by a companion low rise office development, on the south by County Road 10, and on the west by Brooklyn Boulevard. The college currently occupies approximately 2,300 sq. ft. and would be incorporating an additional 2,000 sq. ft., giving them five classrooms and a student lounge area. Cardinal Strich College specializes in providing working adults with graduate level business, computer enhanced education in a night school setting. The classroom hours of operation are 6:30 p.m. to 9:30 p.m. and the college has a limit of 15 students per class. . The additional space would allow 30 more students to the existing 45 student capacity. An educational use such as this was determined to be a special use in this zoning district when Metropolitan State University at 6300 Shingle Creek Parkway was approved under Planning Commission application No. 92011 in August of 1992. The Building Official has reviewed the proposal with respect to building code requirements for such an occupancy. His main concerns are occupant load and exiting. He has indicated that the floor plan submitted complies with code requirements and is acceptable. There will be a need for review of the sewer availability charge (SAC) from the Metropolitan Waste Control Commission (MWCC) for a possible increase. There had been some discussion in 1992 about a possible parking formula amendment related to educational uses. No action was taken to modify the parking requirements, and the experience with Cardinal Strich College at this location has not indicated a need to provide additional parking, although classroom hours are limited to evening hours when the remainder of the building is at its lowest level of use. Attached is a copy of the Standards for Special Use Permit, Section 35-220, Subdivision 2 of zoning ordinance. The granting of a Special Use Permit is to be consistent with these standards. We do not believe that this proposed expansion conflicts with these standards. A public hearing has been scheduled for this application and notices have been sent. • 3-16-95 1 6 i RECOMMENDATION The requested Special Use Permit amendment appears to be in order and approval is recommended, subject to at least the following conditions: 1. The amended Special Use Permit is issued to the applicant on behalf of Cardinal Strich College to operate an expanded night school in the Brooklyn Crossing office building at 3300 County Road 10. The school shall be allowed to occupy 4,300 sq. ft. of rentable space on the fourth floor as indicated in the applicant's submittal. Any alteration or expansion of the school use within the office building, shall require an amendment to this Special Use Permit. 2. The applicant shall receive a sewer availability charge determination from the MWCC and final approval from the Building Official with respect to exiting and occupancy prior to the issuance of a building permit for this expansion. 3. Classes shall be held between 6:00 p.m. and 10:00 p.m. weekdays and on weekends. No weekday day time classes are acknowledged by the approval of this amended Special Use Permit. 4. The amended Special Use Permit is subject to all applicable codes, ordinances and regulations, any violation thereof shall be grounds for revocation. 3-16-95 2 �� /I/I� . 1111 ' �� �������►,tea► ...,�;�,,S:;.y,.,fi ;�'�- ; _ , Islas so ARM NINE ZERO, mm w iww �►� �Iyl iww ar wg w l �r X11111 1C , • • �� ir MR w �■ w w — c.wf �_ 11 - - - - - m y� Ell IPPR MINNS mills of Own 2 Ell 1(�trr.wl.•w2� � �9 � � 1111 ' 1� '1 1111�l I�1 ! �i;.� NMI a � 22 _ r GNW PY NO VI I l• ° o: 1 ABBOT lot�r�vim` '1�,� ��'r l (• y :t MIR i�� �. � .i:. � _ � r � _ �#�►- i` f. 000>0> Z\ -_a'� y-. �_ :;� = %• �`++YY t° �) �t I Cpl � C 3 r j Z-- 3 o i fi+t-t 1 1 1 1 1 1=1�� •� I I n I I It<1 1 TN o • ��y� �Fi �� T L I�j ."� ________l_ _____ .�_ f�l R rtZ e I - - o ..�•., .4 r J x 74 2 O - w S Q o' ' LVN a ° 1 �' CSM Corporation MiALOOM A mnoom tMr F._._wr r a~ow MIM.Mr CSM Corporation —�' 2561 Territorial Road•St. Paul, MN 55114-1500.612/646-1717•FAX 6121646-2404 Via Messenger March 2, 1995 Mr. Ron Warren City of Brooklyn Center 6301 Shingle Creek Parkway Brooklyn Center, MN 55430 Re: Amendment to Special Use Permit (Application No. 92015) Brookdale Office Park Partnership Dear Mr. Warren: Enclosed with this letter please find our application for an amendment to the above-referenced Special Use Permit, as well as the application fee and required documents depicting the requested change. You may recall that in the Fall of 1992, Brookdale Office Park Partnership requested and received a Special Use Permit allowing the operation of a college at the Brooklyn Crossing Office Building. The Cardinal Stritch College operation, which specializes in providing working adults with graduate level business, computer-enhanced education, has proved very successful and Cardinal Stritch wishes to add two additional classrooms at Brooklyn Crossing, while extending its occupancy for an additional three years. The additional classrooms would allow Cardinal Stritch College to add 30 students to its existing 45 student capacity, given its enrollment limit of 15 students per class. The expanded area would add 2,000 square feet of classroom space to its existing 2,300 square feet of space. All other provisions of the existing Special Use Permit, including the limited hours of operation, conformance with all applicable codes, ordinances and regulations, and subjection to additional sewer availability charges, would remain unchanged. In summary, we feel that the expansion of the successful Cardinal Stritch College program would benefit the college, its students, the building and the City of Brooklyn Center, by providing needed classroom space for adult education. Please feel free to contact me if you have any questions regarding our application. Sincerely, , Bruce Carland &roperty Manager Enclosure Section 35-220. SPECIAL USE PERMITS 2. Standards for Special Use Permits A special use permit may be granted by the City Council after demonstration by evidence that all of the following are met: (a) The establishment, maintenance or operation of the special use will promote and enhance the general welfare and will not be detrimental to or endanger the public health, safety, morals, or comfort. (b) The special use will not be injurious to the use and enjoyment of other property in the immediate vicinity for the purposes already permitted, nor substantially diminish and impair property values within the neighborhood. (c) The establishment of the special use will not impede the normal and orderly development and improvement of surrounding property for uses permitted in the district. (d) Adequate measures have been or will be taken to provide ingress, egress and parking so designed as to minimize traffic congestion in the public streets. (e) The special use shall, in all other respects, conform to the applicable regulations of the district in which it is located. 3. Conditions and Restrictions The Planning Commission may recommend and the City Council may impose such conditions and restrictions upon the establishment, location, construction, maintenance and operation of the special use as deemed necessary for the protection of the public interest and to secure compliance with requirements specified in this ord- inance. In all cases in which special use permits are granted, the City Council may require such evidence and guarantees as it may deem necessary as part of the conditions stipulated in connec- tion therewith. 4. Resubmission No application for a special use permit which has been denied by the City Council shall be resubmitted for a period of twelve (12) months from the date of the final determination by the City Council; except that the applicant may set forth in writing newly discovered evidence of change of condition upon which he relies to gain the consent of the City Council for resubmission at an earlier time. 5. Revocation and Extension of Special Use Permits When a special use permit has been issued pursuant to the pro- visions of this ordinance, such permit shall expire without further action by the Planning Commission or the City Council unless the applicant or his assignee or successor commences work upon the sub- . ject property within one year of the date the special use permit is granted, or unless before the expiration of the one year period the applicant shall apply for an extension thereof by filling out and submitting to the Secretary of the Planning Commission a "Special Use Permit" application requesting such extension and paying an additional fee of $15.00. Special use permits granted pursuant to the provisions of a prior ordinance of Brooklyn Center shall expire within one year of the effective date of this ordinance if construction upon the sub- ject property pursuant to such special use permit has not commenced within that time. In any instance where an existing and established special use is abandoned for a period of one year, the special use permit re- lated thereto shall expire one year following the date of abandon- ment. Planning Commission Information Sheet Planning Commission Application No. 95004 Applicant: VenStar Corporation for General Litho Services, Inc Location: West of Parkway Circle, north of the Holiday Inn Request: Site and Building Plan Approval The applicant, VenStar Corporation, is seeking site and building plan approval to build a 60,090 square foot building for General Litho Services, Inc., a printing operation, on a 6.25 acre site located west of Parkway Circle, north of the Holiday Inn. The property in question is zoned I-1 (Industrial Park) and printing, publishing and allied industries are listed as permitted uses in this zoning district. The site is bounded on the north by the Metropolitan Commission Transit Operation's garage and the Spec 10 office/industrial building which houses the Target Audit Division as its principle tenant; on the east by Parkway Circle (a non-public roadway serving as access to the buildings in this area) with a central parking lot serving buildings in the area on the opposite side; on the south by the Holiday Inn; and on the west by Shingle Creek and its accompanying green strip area. ACCESS/PARKING Access to the property is gained via Parkway Circle from Shingle Creek Parkway. Two driveways, one at the southeast corner of the site and the other a shared access with the building to the north at the northeast corner of the site, provide vehicle access to the proposed,facility. Parking on the site would include 140 parking spaces located on the north, east and south sides of the proposed building. The parking requirement for an industrial use with an office component is a combination of both the office and industrial parking formulas based on the square footage devoted to each use. The office parking requirement is one space for every 200 square feet of gross floor area, while the industrial parking requirement is one space for every 800 square feet of gross floor area or 1 parking space for every two employees in the industrial area at the maximum shift. In this case, General Litho proposes to have 12,000 square feet of office (3,000 square feet on the first floor and 9,000 square feet on the second floor of the office portion of the building) and 48,090 square feet in the production/ manufacturing/warehouse portion of the building. This breakdown would require 120 parking spaces, 60 for the industrial area (48,090 divided by 800) and 60 for the office area (12,000 divided by 200). The applicant has indicated that there would not be more than 70 employees (both office and production) at any one shift, therefore, the employee part of the parking formula is not utilized. The plan calls for 20 additional parking spaces along the north property line which are accessed from the abutting property to the north. These parking stalls will be dedicated as off-site accessory parking for the sole use of the adjoining property. Currently there is a special use permit which was granted by the City Council under Planning Commission 3-16-95 1 J Application No. 87007 to provide 153 potential parking spaces on the applicant's property for the sole use of the neighboring property to the north to allow the Target Audit Division office occupancy of that building. A continuation of the off-site accessory parking agreement for 20 spaces will be required and an amended special use permit for use of additional off- site accessory parking on Parkway Circle and in the central parking lot will have to be accomplished. A special use permit acknowledging the amended parking agreement for this area will have to be approved by the City Council and filed with Hennepin County prior to the issuance of building permits for the General Litho building. The on-site parking areas, as well as the twenty off-site spaces are bounded by B-612 curb and gutter and meet the minimum requirements for stall width and depth for 90 degree parking. Appropriate parking protection areas and 24 foot wide drive lanes are also provided. The Engineering Department recommends that a wider radius be provided for the driveways leading to Parkway Circle. A loading dock area containing three loading berths is provided at the southwest corner of the building. A minimum of three berths are required for a manufacturing facility of this size. The loading berths exceed the minimum size requirements in the zoning ordinance. GRADING/DRAINING/UTILITIES The drainage plan proposes to surface drain the parking lots onto Parkway Circle, into a drainage swale on the north and west side of the property and into a storm water detention pond at the southwest corner of the site. This sheet drainage is unacceptable to the Engineering Department which will require storm water be conveyed via storm sewer to these areas. It is my understanding that no information has been provided for roof drainage so that this can also be incorporated into the drainage plan. These modifications will need to be made to the drainage plan in a manner acceptable to the Engineering Department prior to the issuance of a building permit for this project. This site is over five acres and also abuts Shingle Creek which are two criteria requiring Shingle Creek Watershed Management Commission review and approval of a storm water plan for this property. The applicant will be required to have such a plan approved prior to the issuance of building permits. Easements for ponding areas will also be required. The Commission's attention is directed to the area designated on the plan as the "edge of wetland". This area has been verified and is subject to wetland regulations. Also, it should be noted that the 100 year flood elevation for Shingle Creek is 844 feet. The lowest finished floor elevation for a building on this property must be at least one foot above this elevation. The proposed finished floor elevation is 850 feet, well above the 100 year flood elevation. No grading, filling or alteration of the area at or below the 844 foot mark may take place without the granting of a special use permit by the City Council and the providing of compensating storage. No alteration is proposed at this time in this area, however, the applicant is contemplating a future 20,000 square foot addition to the west end of the building which will require filling in the area and wetland mitigation. The applicant will 3-16-95 2 have to seek appropriate approvals such as a special use permit and watershed commission approval for filling and wetland mitigation before such an expansion, or grading for it can be authorized. In the meantime they are only seeking approval of a grading plan that will allow the construction of the proposed 60,090 square foot building. Sanitary sewer and water will be provided to the building at the north end of the site. Again, the final drainage, grading and utility plan is subject to the approval of the Engineering Department and the Shingle Creek Watershed Management Commission. LANDSCAPING The applicant has submitted a landscape plan in response to the landscape point system used to evaluate such plans. This site is 6.25 acres and requires a minimum of 405 landscape points. The applicant's proposal calls for exactly 405 landscape points through the use of a combination of 20 shade trees (200 points), 20 coniferous trees (120 points), 20 decorative trees (30 points) and 110 shrubs (55 points). The applicant has requested not to be required to designate the species of tree, shrub, etc., but wishes to have the option open to make a determination of the species to be used at the time of bidding of the project. We do not have a problem with this, but would recommend that the applicant designate the various types of trees and shrubs under the categories proposed. The plan calls for a 15 ft. green strip along the Parkway Circle access drive between the two access points. This area will be sodded and contain landscaping including shade trees, coniferous trees, decorative trees and shrubs. Appropriate sight lines should be maintained at the access points to Parkway Circle to avoid potential sight visibility problems. The proposed landscaping seems to be well distributed around the site, particularly in the front and south green strips. Some plantings are also proposed for the area to the west of the building close to the edge of the designated wet land area. Underground irrigation is required in all landscaped areas. The area to the west of the building will be left in a more natural state as part of their plan. BUILDING The building exterior is proposed to be a precast concrete with an exposed aggregate finish along the east end where the office area is. The office area is a two story area with the second floor being totally office space and the first floor being part office and part production. The production or industrial portion of the building exterior is proposed to be also precast concrete with a raked finish that will be painted to be complimentary to the exposed aggregate finish. The Planning Commission may wish to discuss the exterior treatment being proposed. It should be noted that the buildings in this area for the most part have a brick exterior including the Minnesota State High School League office, the Holiday Inn, the building immediately to the north of this site, which contains the Target Audit Division, and Parkway Place, which fronts along Shingle Creek Parkway between the two access points for Parkway Circle. The Spec 11 building site is a decorative concrete block building. The question is whether or not the exterior treatment proposed by the applicant is consistent and in keeping with the building exteriors in this area. The building elevations 3-16-95 3 a show the building to be approximately 24 ft. in height with a two story office component on the east end of the building and an approximate 23 ft. high manufacturing/production/ warehousing component to the west. At the main entrance to the building is an approximate two story canopy area. Tinted insulated glass in anodized aluminum thermal break frames are provided around the south, east and north portions of the two story office area. LIGHTING/TRASH The applicant's site plan indicates 250 watt high pressure sodium wall mounted light fixtures around the building. Two on-ground light fixtures that provide building up-lighting are located in the front of the building (east side). Two 250 watt high pressure sodium lights are mounted on 30 ft. high light poles in the green strip area along Parkway Circle. These fixtures will be directed onto the property and should not create glare. The plans do not show a location for trash, however, it is anticipated that trash facilities will be located in the area of the loading docks. A screening device, preferably of the same material as the building, will be required to screen trash containers from public view. RECOMMENDATION The plans, with possible exception, of the exterior treatment, appear to be in order. Approval is recommended subject to at least the following conditions: 1. The building plans are subject to review and approval by the Building Official with respect to applicable codes prior to the issuance of permits. i 2. Grading, drainage and utilities plans are subject to review and approval by the Engineering Department prior to the issuance of permits. 3. A Performance Agreement and supporting Financial Guarantee (in an amount to be determined by the City Manager) shall be submitted prior to the issuance of permits. 4. Any outside trash disposal facilities and rooftop mechanical equipment shall be appropriately screened from view. 5. The building is to be equipped with an automatic fire extinguishing system to meet NFPA standards and shall be connected to a central monitoring device in accordance with Chapter 5 of the city ordinances. 6. An underground irrigation system shall be installed in all landscaped areas to facilitate site maintenance. 3-16-95 4 01 7. Plan approval is exclusive of all signery, which is subject to Chapter 34 of the city ordinances. 8. B-612 curb and gutter shall be provided around all parking and driving areas. 9. The applicant shall submit an as-built survey of the property, improvements and utility service lines prior to release of the Performance Guarantee. 10. The property owner shall entry into an easement and agreement for maintenance and inspection of utility and storm drainage systems, prior to the issuance of permits. 11. The applicant shall provide appropriate erosion and sediment control devices on the site during construction as approved by the Engineering Department. 12. The storm drainage system shall be approved by the Shingle Creek Watershed Commission prior to the issuance of permits. 13. Ponding areas required as a part of the storm drainage plan shall be protected by an approved easement. The easement document shall be executed and filed with Hennepin County prior to the issuance of permits. 14. The 20 parking stalls indicated on the north side of the site shall be dedicated as off-site accessory parking for the sole use of the adjoining property. Said declaration shall be filed with the titles to the property prior to the issuance of permits. 15. An amended Special Use Permit for off-site accessory parking on Parkway Circle, the central parking lot and adjoining areas relieving the subject property of its 153 parking stall dedication shall be granted and an appropriate amendment to the easement agreement and declaration of covenants relating to these properties shall be executed and filed with Hennepin County prior to the issuance of permits for this project. 16. All work performed and materials used for construction of utilities shall conform to the City of Brooklyn Center's current standard specifications and details. ` 3-16-95 5 M • • , Application No. �IIIII � 4 ` ME—Al MEN Eggs mr Ing ME �,•, II11 iiiiq •\ `� iii,, / ••, \ � � :�♦� i gig hit if if it� t == ; £ • �'ii 3# 3i , t! I I f s � sfie •c= �' ` � fit. � � ! � +I� �t �� ; �s3 °i Y ; Iti . i lot �'il it iit C 1i 11 11 fib ` rp 1 :1g•seeeaE�ti�•+ I 7 v i tP ti Q 9 C7 s;` to •!• s i�' r {0 /_igg f j n I moo> • E r m ;'• a C TRACT 0 Rig N0. 1864 '•-:':s � > ,. j y.. •.�_ > - +r':i y , vi r � rr a ^.s. .1 T _t ,.r x� �. 3 - � d i Oil At 1111 1111111+ \ g / I; (• i — � — e, ,�' 1 ml +1111, 1111 { >,o I --�1 ` ✓i'9 1111 e r�j i n�• Tom' �'�1\ I '' � s l i / , -- 1 _ - a the I ( I ..!m _ in I R L iSt1N6 R3k4 1 i F3 P o I e 19 UZI R p' r----------\ —\ \\ I 1 I � 1 *2j, • I ' or w I.0 .w w •wr I I� ii i i I � I + � '..I � �I I I I• ! I l l l l l l i l I I I i l III !• fill,• ! i�� LRISTIM6 ROA1 !�a 1s<r� ■ i ! ;11l: '■ ' Y Dili ! :w�wa•c i A 1 MMM& uTw sates, nrc. �.:�.�. cwwn*#Amu ♦ 1 ♦ ® ♦a \ ♦♦.�. ♦ ♦ w I_ i � j ♦ s I I i I i ' I 1 I i ss o n �v s � � • I � ! 1 • � w .■w.w � w I Y. i I_ 1 '� I .■w.rr i t � � I 1 I i• � ■ rs-. rte-• Ili � � � � ii � iliil� i ► i � � � i � 911E7I110 ROAD • 0 OIWW[ AFAR=Cotmum L 1 P, racmt, A°'' vast.:. C4wp. am PLO GZMEM ISlSO IIm PA am tlOD CafW. mmosm Ra Imb !lAYYM.11■rr�. M tt 1r.��Iti�Y. w 4 w 4 w w w 1 1 1 1 I I 1 al i I I 1 1 I I I I 1 I 1 1 I 1 I I 1 I I� N -+- I I� ! i I I 1 I I 1 1 u t � ' 1 o 0 o b AV=COMYrAM A20* FLOaB . L r,��a� vm cow. cast ra�o �n� n�c. .. P ■M11p a.rs Ir1s 40 • w I p I-IT I 1 I 1 I i I N , V I ! I ;c c� I • - o ._ 1 � a I I a 1 � 1 T I ! I� I ` I , I — � i i IIi I it plot=CORAVIlim ill � I LA 3 _ --- yaw �/r c�tca c� rus�o s�vacas, nFC. '�:�:.�' lIA� Pl11i9 11 [Illpl� _ .�,� _ � _ CIIIIII� .r ■ ■ �j 131 3 1 Pr 7 7 v►' i vl►