HomeMy WebLinkAbout1984 10-04 PCP Planning Commission Information Sheet
Application No. 84033
Applicant: Lombard Properties
Location: 6765 Shingle Creek Parkway
Request: Site and Building Plan/Special Use
The applicant requests site and building plan and special use permit approval to
construct a 75,109 sq. ft. office-industrial building on Tract B, R. L. S. 1564,
immediately west of the Spec. 11 industrial building. The property in question is
zoned I-1 and is bounded by MTC on the west, by the Spec. 9 industrial building on
the north, by the Spec- 11 industrial building on the east, and by vacant I-1 zoned
land on the south to be used for a central parking lot and another office-industrial
building. Office use of a significant nature apart from an industrial use is a
special use in the I-1 zoning district. A similar use was approved for the Spec.
14 building under Application No. 84009.
The proposed Spec. 10 building is to gain access from the main 48' wide driveway
which surrounds the central parking lot and Spec. 14 site. Parking for the develop-
ment is based on 50% office use and 50% industrial use. The total parking requirement
is (37,554.5 t 800) = 47 + (37,554/37,554.5 x .0005 + 190) = 180 = 227 spaces. Of
these 227 spaces, 175 are to be provided on-site and 52 from the central parking lot.
This is more parking on-site and less off-site than was comprehended under the ori-
ginal approval for Spec. 10 with Application No. 80016. Preliminary layouts for
Spec. 10 and Spec. 12 would so reduce the need for off-site parking that it would
appear no ramp would be required to fulfill ordinance requirements, even with 50%
office occupancy. This is accomplished basically by going with somewhat smaller
buildings and much smaller loading dock areas. Five handicapped stalls are provided
near the building as required by code.
The landscape plan provides for a number of shrubs immediately adjacent to the
building and some larger decorative trees (Crab, River Birch, Buckthorn and Cranberry)
in the larger traffic islands on the site and in the central parking lot. A number
of planting beds adjacent to the building are to be planted with Pachysandra flowers.
The landscape plan also calls for a number of plantings (shrubs and decorative trees)
within a large green area in the central parking lot that is to serve as a deferred
parking area. Plantings are also scheduled in an open emergency drainage way between
rows of parking south of the building.
The grading plan provides that drainage will tend to flow toward the main traffic
island south of the building. Catch basins along this island and in the central
parking lot will convey runoff through storm sewer to the City system in Shingle
Creek Parkway. In the event of a severe flood, water would also dump into the overland
drainage way within the traffic island and flow, for the most part overland, directly
into Shingle Creek. Bituminous or timber curbing has been indicated in most areas
south of the site (along the outer drive and in the central lot) . Staff recommend
that the curbing along the large outer drive be concrete and that any temporary
curbing within the central lot be bituminous rather than timber curb. Concrete
sidewalk, 5' wide and embedded in the pavement, cross the outer drive and Spec. 10
parking lot, providing an aid to pedestrian traffic. Utility plans do not indicate
a looping of the water lines around the Spec. 10 site. This should be revised to
provide looping prior to issuance of building permits.
10-4-84 -1-
Application No. 84033 continued
The building plans call for 12' clear ceilings. Each tenant area will have access
to a loading berth, but spaces will not necessarily have berths of their own. This
is similar to the Spec. 14 design. The building exterior is to be face brick on
the east, south, and west elevations, with a 3' wide metal sign band about two-
thirds of the way up the wall . The north elevation of the building is to be scored
concrete block painted to match the color of the face brick. A band of the block
will be painted to match the sign band on the other three sides. This combination
of building treatments has been considered in other cases to be a consistent exterior
treatment. Along the south and part of the west elevations, there are to be large
sections of 7' high pre-finished bronze aluminum storefront windows. Pre-finished
bronze aluminum skylights will be provided above major building entrances. Security
lights are indicated above the loading dock areas along the rear of the building.
Site lighting is to be provided by 35' high lightposts indicated at about 200'
intervals within the main traffic island on the Spec. 10 site. No trash enclosures
have been shown on the plan. Generally trash containers need not be screened if
they are not visible from the street. The back of Spec. 10 and Spec. 11 are fairly
open to the street. It is recommended that additional landscaping, such as coni-
ferous trees, be provided in the greenstrip adjacent to Shingle Creek Parkway
between Spec. 9 and Spec. 11 to provide better overall screening of the loading
dock area.
In general , the plans appear to be in order and approval is recommended, subject to
at least the following conditions:
1. Building plans are subject to review and approval by the Building
Official with respect to applicable codes prior to the issuance of
permits.
2. Grading, drainage, utility and berming plans are subject to review
and approval by the City Engineer, prior to the issuance of permits.
3. A site performance agreement and supporting financial guarantee (in
an amount to be determined by the City Manager) shall be submitted
prior to the issuance of permits to assure completion of approved
site improvements.
4. Any outside trash disposal facilities and rooftop mechanical equip-
ment shall be appropriately screened from view.
5. The building is to be equipped with an automatic fire extinguishing
system to meet NFPA standards and shall be connected to a central
monitoring device in accordance with Chapter 5 of the City Ordinances.
6. An underground irrigation system shall be installed in all landscaped
areas to facilitate site maintenance.
7. Plan approval is exclusive of all signory which is subject to Chapter
34 of the City Ordinances.
8. B612 curb and gutter shall be provided around all parking and driving
areas.
9. Plan approval acknowledges off-site accessory parking of up to 52
stalls from the central parking lot as provided for under Application
No. 84034.
10-4-84 -2-
I
Application No. 84033 continued
10. The applicant
shall provide a landscape plan for additional coni-
ferous plantings along the Shingle Creek Parkway and decorative
trees along the greenstrip south of Spec. 11 . This plan shall be
subject to approval by the City Council and shall become a part
of the development plans to be completed prior to release of the
financial guarantee required by Condition No. 3.
11 . The special use permit is subject to all applicable codes, ordi-
nances, and regulations and any violation thereof shall be grounds
for revocation.
12. Special use permit approval acknowledges up to 50% office occupancy
in the Spec. 10 building. Any office occupancy over 50% of the
gross floor area is subject to amended approval of this application
and Application No. 84034.
13. As-built utility surveys for the development shall be submitted to
the Engineering Department prior to release of the financial
guarantee.
14. A cash escrow, in an amount to be determined by the City Manager,
shall be submitted to cover the cost of street cleaning associated
with the placement or removal of fill on the site.
10-4-84 -3-
1
1
Planning Commission Information Sheet
Application No. 84034
Applicant: Lombard Properties
Location: 6765 Shingle Creek Parkway
Request: Special Use Permit / off-site accessory parking
The applicant requests special use permit approval to provide 52 off-site parking
stalls for the proposed Spec. 10 building on the central parking lot serving the
planned commercial industrial area north of Freeway Boulevard and west of Shingle
Creek Parkway. This application is in support of Application No. 84033 for site
and building plan approval . The Spec. 10 development requires a total of 227
parking stalls, 175 of which will be provided on-site. The remaining 52 spaces to
be provided from the central parking lot are the subject of this application.
This application is also an amendment of a previous special use permit for off-site
accessory parking granted under Application No. 82009. That approval acknowledged
up to 121 parking spaces from the central parking lot (Tract C, R.L.S. 1564) for
the use of Spec. 10 (Tract B, R.L.S. 1564) . An additional 112 spaces were allocated
to Spec. 11 . The parking space allocations are again to be rejuggled so that the
need for a 'parking ramp will be less likely. If each parcel were allocated the
minimum necessary to meet parking requirements, the following parcels would be
entitled to the number of spaces shown below:
Parcel Development Allocation from Central Lot
Tract A, R.L.S. 1564 Spec. 11 73 102 at present
Tract B, R.L.S. 1564 Spec. 10 52
Tract A, R.L.S. 1572 Spec. 12 72 (43)
Tract B, R.L.S. 1572 Ramada 61
Tract G, R.L.S. 1572 Spec. 14 82
Total 340
In light of a previously approved plan which provides for 340 parking stalls in the
central parking lot, the above allocation is recommended for approval for the
respective developments, subject to at least the followingcondition:
1. Fifty-two (52) parking stalls to be constructed on Tract C, R.L.S.
1564 shall be legally encumbered to the sole use of Tract B of
R.L.S. 1564. Said encumbrance to be subject to review and
approval by the City Attorney.
10-4-84
Planning Commission Information Sheet
Application No. 84032
Applicant: L. Cramer Company
Location: Southwest corner of I-94 and Brooklyn Boulevard
Request: Special Use Permit Extension
The applicant requests extension of the special use permit approval granted a year
ago for an office condominium development on the R5 zoned parcel at the southwest
quadrant of Brooklyn Boulevard and I-94. The property in question is bounded by
I-94 on the north, by Brooklyn Boulevard on the east and by single-family homes on
the south and west. Access to the development would be off Brooklyn Boulevard only.
Low rise (1-3 storey) office uses are allowed by special use permit in the R5
zoning district.
The proposed use was granted approval under Application No. 83037 on August 22, 1983
following approval of a Comprehensive Plan amendment (Planning Commission Resolution
83-3 and City Council Resolution 83-130) to allow office or mid-density residential
development interchangeably along Brooklyn Boulevard . The project has been delayed
in attempts to line up financing, but should proceed with soil correction this fall
and winter and construction next spring.
The proposed plan is unchanged from that approved last year. Site plan approvals
are not subject to a one-year limitation. Therefore, the primary questions to be
addressed are concerning the office use itself which requires the special use permit
approval . For background on the site development plan , we have included the staff
report and minutes pertaining to Application No. 83037 for the Commission's con-
sideration.
A public hearing regarding this special use permit extension has been scheduled and
notices have been sent. Approval of the extension is recommended with all original
conditions to be continued. In addition, the following condition is recommended:
15. Soil correction and introduction or removal of fill on the
site shall be subject to the issuance of a grading authorization
by the Director of Public Works and the Director of Planning
and Inspection. A cash escrow, in an amount to be determined
by the City Manager, shall be submitted to defray the cost
of street cleaning associated with the site preparation.
10-4-84
1
1