Loading...
HomeMy WebLinkAboutPC78054 - 8/10/78 - 6700 Shingle Creek PkwyF_VING COMMISSION FILE Gam.,... File Purge Date: FILE INFORMATION Project Number: 78a5� PROPERTY INFORMATION Zoning: PLAN REFERENCE Note: If a plan was found in the file during the purge process, it was pulled for consolidation of all plans. Identified below are the types of plans, if any, that were consolidated. • Site Plans • Building Plans • Other: FILE REFERENCE Note: The following documents were purged when this project file became inactive. We have recorded the information necessary to retrieve the documents. Document Twe Date Range Location Agendas: Planning Commission Office Minutes: Planning Commission 8161-78 City Vault Minutes: City Council 8/�/?e City Vault Document Type Number Location Resolutions: Planning Commission City Vault Resolutions: City Council City Vault Ordinances: City Council City Vault COMMERCIAL/INDUSTRIAL PROPERTY FILES CHECKLIST CITY OF BROOKLYN CEN'rER PLANNING COMMISSION 70NING APPLICA110N Application No. 78054 Please Print Clearly or Ttiic� Street Location of Property 6700 Shingle Creek Parkway Legal Description of Property Owner P.nprav Technologv. Div. of Medtronic,_Inc. Address 6700 Shingle Creek Parkway _ "hone No. Applicant Eneray Technology, Div. of Medtronic, Inc. Address 6700 Shingle Creek ParkwayPhone No. Type of Request: Rezoning Subdivision Approval Variance _XX_ Site & ("log. Plan Approval Special Use Permit Other: Description of RegLJeSt: See letter dated July 12, 1978 RE: Pro osed Storage Building Fee $ 25.00 Receipt No. W. Date= of P.C. Consideration: Approved ✓ Mg cored' ions: �A''FF1I E ca s Signature - —August 4 Date PLANNING COMMISSION PECOMMENDATION Den a ed this �,�ti. day of _F(_ t ' — ro l ow- 19 bttrth hat rman CITY COUNCIL ACTION Dates of Council Consideration: Approved Denied this oZ g day of 19 '7C/, with the following amendment: ell P/ I F arm No 18 (over Page 2 We will be prepared to review sketches of Mr. Rosen's proposal for wind breaks and ask for comments from the Commission regarding their, recollection of this concept and whether or not a formal application would be needed to consider this proposal. Item No. 6c - Lund -Martin Lithium Storage Building Application No. 78054 submitted by Lund -Martin Company consisting of site and building plan review of a 20' x 20' freestanding lithium storage building on the Medtronics site at 6700 Shingle Creek Parkway was recently approved by the City Council. Mr. Virgil Florhaug of Lund -Martin has recently contacted us regarding various minor revisions that they would like to make with respect to the.storage building. It is no longer their desire to have the building separated in half with a concrete divider, and -therefore, they do not feel it is necessary to have two doorways leading into the storage structure. They propose to have one door- way on the south side of the structure and an exit doorway on the north side. They also do not feel the elaborate heating and cooling system proposed for the storage building is necessary. Rather, they propose to use a residential type air conditioning unit to control humidity in the summertime and also provide electric heat to maintain temperature control. For this reason, there would be no rooftop mechanical equipment, and they desire to eliminate the parapet proposed for the storage building. I have asked Lund -Martin to submit revised sketches outlining the proposed changes, and have indicated to him that the staff does not object to the proposed amendments. I have also reviewed this briefly with the Fire Chief who does not object to the amendments. We wish to briefly review this with the Planning Commission prior to `., permitting these alterations. 9-28-78 Planning Commission Information Sheet Application No. 78054 Applicant: Lund Martin Company Location: Medtronic, Inc., 6700 Shingle Creek Parkway Request: Site and Building Plan Approval The applicant is seeking site and building plan approval to construct a 20' by 20' freestanding lithium storage building on the Medtronic site at.6700 Shingle Creek Parkway. Presently lithium is stored in air tight containers located in a non- sprinklered area in the southeast portion of the building. Lithium reacts violently when exposed to water and, therefore, is stored in areas that have other fire extinguishing systems. The building would be located approximately 40 ft. from the existing building, and would be constructed with 12 inch concrete block. No sprinklers would be provided in the building, but other fire detection systems would be supplied. The Fire Chief has reviewed the plan and is familar with lithium. He has suggested, and the applicant has concurred, that heat and smoke detectors connected to a centrally monitored alarm system should be installed. A letter from Mr. Pete Wilcken of Medtronics is attached explaining further the reasons for wanting the addition for outside storage space. The plans seem to be in order and approval is recommended subject to the following conditions: 1. Building plans are subject to review and approval by the Building Official with respect to applicable codes prior to the issuance of permits. 2. Any grading, drainage, utility and berming plans are subject to approval by the City Engineer prior to the issuance of permits. 3. The proposed building will be equipped with a lithium -type fire extinguisher inside the door of each section of the proposed storage building. 4. Heat and smoke detectors will be provided in each section of the building and be connected to an approved fire monitoring system. 5. Any rooftop mechanical equipment exceeding the height of the proposed parapetshall be appropriately screened from view. Medtronic, Inc. 3055 Old Highway Eight P.O. Box 1453 Minneapolis, Minnesota 55440 IVledtronic Telephone tro c Telex61 : Cable: Medtronic Telex: 29-0598 w July 12, 1978 Medtronic's Phone Number has been changed to: 612/574-4000 City of Brooklyn Center 6301 Shingle Creek Parkway Brooklyn Center, Minnesota 55430 Attention: Director Planning and Inspection Re: Proposed Storage Building Energy Technology, Div. of Medtronic, Inc. 6700 Shingle Creek Parkway Brooklyn Center, Minnesota Gentlemen: We are submitting two copies of a plan showing location and design of the Proposed Storage Building for lithium for use in our manufacturing process. Lithium reacts violently when exposed to water and thus is shipped and stored in airtight containers which can only be opened in our dry room. We have been concerned for some time about the risk in- volved in the presently used method of storing lithium within our building. After investigating all available options with a variety of consultants we have concluded that the construction of a small uniquely designed build- ing that will be detached from our main facility is the best alternative. Our position is not only based on the desire to minimize the potential risk of a fire but also to provide the best possible circumstances for extinquish- a fire should one occur. We of course will be most appreciative of any recommenda- tions you can offer to increase the benefit of the proposed structure. In addition, we are prepared to act on any reason- able recommendation that will make this building aestheti- cally pleasing and compatible with the surrounding area. Page two City of Brooklyn Center July 12, 1978 We would appreciate your prompt review on this matter. If you have any questions or desire additional information, please contact us. Sincerely, MEDTRONIC, INC., 1 C. A. "Pete" Wilcken, Jr., P.E. Corporate Plant Engineering Manager cc: Lund Martin Co. CAW/db 'ON zi AV -1-V wij,