HomeMy WebLinkAboutPC85024 - 9/12/85 - 6000 Shingle Creek PkwyPLANNING CONMMSION FILE CHECKLIST
File Purge Date: 81r 9s`
FILE INFORMATION
Planning Commission Application No. 85°2`q
PROPERTY INFORMATION
Zoning: C Z-
PLAN REFERENCE
Note: If a plan was found in the file during the purge process, it was pulled for
consolidation of all plans. Identified below are the types of plans, if any, that were
consolidated.
• Site Plans
• Building Plans
• Other: ✓ parkrn plow
101YIs�apli, 9
FILE REFERENCE
Note: The following documents were purged when this project file became inactive. We
have recorded the information necessary to retrieve the documents.
Document Type Date Range Location
Agenda Cover Sheet: Planning Commission Agenda Book
Minutes: Planning Commission 91;21B5` City Vault
Minutes: City Council 9�,23/83` City Vault
Resolutions: Planning Commission City Vault
Resolutions: City Council City Vault
Ordinances: City Council City Vault
Historical Photographs: Planning Commission City Archieve
CITY OF BROOKLYN CENTER
PLANNING COMMISSION APPLICATION
Application No. 85024
Please Print Clearly or Type
Street Location of Property 6WF0 Shingle Creek Parkway
Legal Description of Property Lot 1, Block 1, Shingle Creek Center
Owner Ryan Construction Company of Minnesota, Inc.
Address 900 Second Avenue South #700, Mpls., MN 55402 Phone No. 339-9847
Applicant Ryan Construction Company of Minnesota, Inc.
Address 900 Second Avenue South #700, Mpls., MN 55402 Phone No. 339-9847
Type of Request: Rezoning
Variance
X Special Use Permit
Subdivision Approval
Site & Bldg. Plan Approval
Other:
Description of Request: Convenience restaurant with a drive -up service window.
The applicant requests processing of this application and agrees to pay to the City of
Brooklyn Center, within fifteen (15) days after mailing or delivery of the billing state-
ment, the actual costs incurred by the City for Engineering, Planning and Legal expenses
reasonably and necessarily required by the City for the processing of the application.
Such costs shall be in addition to the application fee described herein. Withdrawal of
the application shall not relieve the applicant of thobligation to pay costs incurred
prior to withdrawal.
Fee $ 50.00
Receipt No. 68483
Date:" August '30, 1985
PLANNING COMMISSION RECOMMENDATION
GG2--
licant s Signature
Dates of P.C. Consideration:
Approved Denied this _LZ�— day of 19(?�, subject to the
following conditions: Z-)
CITY COUNCIL ACTION
Dates of Council Consideration:
n
Approved Denied this day of 19 S!! , with the following
amendment:
v pie
P/I Form No. 18 (over please)
Planning Commission Information Sheet
Application No. 85024
Applicant: Ryan Construction
Location: Shingle Creek Parkway and John Martin Drive
Request: Site and Building Plan
The applicant requests site and building plan and special use permit approval
to construct asmall shopping center and restaurant at the northeast corner of
Shingle Creek Parkway and John Martin Drive. The land in question is zoned
C2 and is part of the Target development east of Shingle Creek Parkway between
John Martin and Summit Drives. The proposed restaurant is to have a drive -up
window and is, therefore, classified as a special use in the C2 zoning district.
The total development, being constructed with common access and parking includes
Target at 105,928 sq. ft., Building A of the Shingle Creek Center at 32,400
sq. ft. and Building B of the Shingle Creek Center at 8,400 sq. ft. Building
A is attached to Target and is slightly smaller than was approved under Applicaticn
No. 85001, while Building B now includes 5,360 sq. ft. of retail space and a
3,040 sq. ft. restaurant rather than simply a 4,500 sq. ft. restaurant as was
approved under Application No. 85001.
The major accesses for the Target/Shingle Creek Center development are unchanged
from the previous site plan. However, the new site plan shows two accesses
to the LaBelle's property. One is primarily for truck traffic along the jog
in the easterly property line, at the northwest corner of the LaBelle's site.
The other is about 110' north of John Martin Drive and connects the two parking
lots. Staff feel that both these connections are beneficial in that they will
reduce unnecessary turning movements onto and trips on the public streets.
The parking requirement for the total Target/Shingle Creek Center development
is complicated, to say the least. The approach agreed upon by the staff and
the developer (Ryan Construction) is to apply the retail formula to all floor
space within this common development and then to require additional parking
for the restaurant after certain credits have been accounted for. Total floor
area in the development is 146,728 sq. ft. Under the retail parking formula,
this requires 855 parking spaces. The restaurant requires 64 spaces for 116
seats and 12 employees (calculated at 1:2 for each). Credits are allowed, however,
for 840 sq. ft. of the restaurant (10% of the floor area of Building B). This
represents 27.6% of the floor area of the restaurant. Exempting 27.6% of the
restaurant parking requirement reduces parking by 17.7 spaces. In addition,
the balance of the restaurant has already been allocated 12.1 spaces under the
retail formula. These may also be credited. The net parking requirement for
the entire development is, therefore, as follows.
Total Floor
Space @ Retail
855
spaces
Restaurant
@ 1:2
64
spaces
10% G.F.A.
Credit Bldg. B
-17.7
spaces
Restaurant
Parking Provided at Retail
-12.1
spaces
889.2
spaces
The plan submitted provides 891 spaces for the entire development. It should
be noted that the heavier parking requirements assessed against the initial
30,000 sq. ft. of retail space are borne by the Target property. The retail
space for Building A and B is calculated entirely at 5.5 spaces per thousand
sq. ft. of gross floor area. Staff have not calculated each building separately,
although they will all be on separate parcels, because the entire development
is tied together by common access and cross -parking arrangements. It is, therefore,
considered to be basically one common development.
9-12-85 -1-
Application No. 85024 continued
The remainder of this report will deal chiefly with Building B, since there
are virtually no changes in the Target aspect of the development, and only minor
changes in Building A. Building B is to have a driving lane on all sides. The
restaurant is to be located on the west end of the building with a drive -up
window along the west side. The front of the building is toward the north; the
rear faces John Martin Drive. The exterior treatment is entirely of brick.
A trash enclosure is shown east of the restaurant, on the south side of the
building. It is to be enclosed by a masonry wall and iron gate. A small court
for delivery vehicles is provided within the south side of the building.
No grading, drainage and utility plans have been submitted with this application.
No significant changes are anticipated. Staff would recommend some additional
delineators for parking behind Building A. The proposed landscape plan shows
the same number of shade trees, though a slightly different specie mix, and
an expanded variety of shrubs and conifers. The area behind the back of Building
B, however, is not adequately screened by landscaping. It is recommended that
at least 4 to 5 coniferous trees be added in this area of the greenstrip.
Regarding the special use standards, staff see no conflict resulting from the propos-
ed drive -up window• It would probably be preferable if the window were away from
Shingle Creek Parkway, but there is probably no direct diminution of property
values resulting from it. The prospective tenant is a pizza restaurant which
will probably not generate significant drive -up traffic. Because of the size
of the overall development and the distance to accesses, there should be no
traffic congestion in the public strees related to the drive -up facility.
Altogether, the plans are in order and approval is recommended, subject to at
least the following conditions:
1. Building plans are subject to review and approval by the Building
Official with respect to applicable codes prior to the issuance
of permits.
2. Grading, drainage, utility and berming plans are subject to
review and approval by the City Engineer, prior to the issuance
of permits.
3. Any outside trash disposal facilities and rooftop mechanical
equipment shall be appropriately screened from view.
4. The building is to be equipped with an automatic fire extinguish-
ing system to meet NFPA standards and shall be connected to
a central monitoring device in accordance with Chapter 5 of
the City Ordinances.
5. An underground irrigation system shall be installed in all land-
scaped areas to facilitate site maintenance.
6. Plan approval is exclusive of all signery which is subject to
Chapter 34 of the City Ordinances.
7. B612 curb and gutter shall be provided around all parking and
driving areas.
8. The plans shall be modified prior to consideration by the City
Council to indicate:
a) Parking delineators as required by the City Engineer.
9. Driveway layout for the drive -up window shall be subject to
review and approval by the City Engineer prior to the issuance
9-12-85 of building permits. -2-
PWOPOSED ROADWAYS
PROPOSED DRtDGr-S
c I CY
"'K
eA,
x
Application No
- - --------------
%\
to
s 1�0 C) I
listProdudsCo.,hw., PQ Box26303, Richmond, Virginia23260 804/261-2000
August 9, 1985
Mr. Jeffrey Rice
Ryan Construction
700 International Center
900 Second Avenues South
Minneapolis, Minnesota 55402
Re: Brooklyn Center - Target/LaBelle's
Reciprocal Easement Agreement
Dear Jeff:
As discussed on the phone, LaBelle's is willing to give a truck
easement to Target across our parking lot under the following
conditions:
1. That the easement be reciprocal and that LaBelle's trucks may
travel across the rear of Target's property via Summit Drive
North.
2. That a curb cut will be placed in a mutually agreeable area
so that traffic can flow between the two properties without
exiting onto John Martin Drive. I understand that you will
be forwarding to me a proposed location for this curb cut.
3. LaBelle's reserves the right to place a pylon/monument sign
on your property near the intersection of John Martin Drive
and Shingle Creek parkway. This right is conditioned upon
the city's approval, Ryan Construction's approval (which will
not be unreasonably withheld), and all costs of the pylon
sign including installation will be borne by LaBelle's.
I would appreciate it if you would have your attorneys draft an
Easement Agreement incorporating the above and forward it to my
attention. Since we have a,team of attorneys who work on the Best
account, we have not assigned one specific attorney to handle this
matter. However, I will let you know as soon as possible who the
appropriate attorney to contact will be.
;e truly yours,
orah H. Beer
Supervisor of Real
cc: Bob Thompson
Carol Carol
Chuck Yeager
DB/dg
Estate Analysis